| Parámetro | Valor |
|---|---|
| corriente continua | 99% (STOP0); min. 60% (STOP1) |
| PL | up to e (STOP0); up to d (STOP1) |
| EAN | 4048879367592 |
| SIL | up to 3 (STOP0); up to 2 (STOP1) |
| AC-15 | 6 A (230 V AC) STOP0; 3 A (230 V AC) STOP1 |
| DC-13 | 6 A (24 V DC) STOP0; 2 A (24 V DC) STOP1 |
| Clase electrónica | 27371819 |
| N.º de artículo: | 3000-33113-3020060 |
| Categoría | up to 4 (STOP0); up to 3 (STOP1) |
| Conexión | Spring clamp plug-in terminals |
| Vida útil | 20 years |
| Corriente de entrada | max. 7.1 VA/3.2 W (with monitoring output) |
| Voltaje de entrada | 24 V DC (-15 +20%), 24 V AC (-15 +10%) |
| Unidad de embalaje | 1 |
| Método de montaje | DIN-rail mountable (EN 60715) |
| Material de contacto | Ag Sn O, self cleaning, positively driven |
| Tensión de conmutación | max. 250 V AC/DC |
| Rango de temperatura | -25...+60 °C (storage temperature -40...+85 °C) |
| país natal | DE |
| Vida mecánica/electrónica | 10 000 000 switching cycles/load dependent |
| Producto alternativo: | Product Comparison6 A (STOP1); 8 A (STOP0)Protection-door and emergency-stop controlLight curtain controlSafety magnetic switch controlAutomatic/manual/manual monitored reset/startInputInput voltage24 V DC (-15 +20%), 24 V AC (-15 +10%)Input currentmax. 7.1 VA/3.2 W (with monitoring output)Safety IndicatorsPLup to e (STOP0); up to d (STOP1)Categoryup to 4 (STOP0); up to 3 (STOP1)DC99% (STOP0); min. 60% (STOP1)SILup to 3 (STOP0); up to 2 (STOP1)Service life20 yearsUtilization categorySafety contacts (STOP 0)max. 250 V AC/8 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppressionSafety contacts (STOP 1)max. 250 V AC/6 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppressionAC-156 A (230 V AC) STOP0; 3 A (230 V AC) STOP1DC-136 A (24 V DC) STOP0; 2 A (24 V DC) STOP1General dataMech./ elect. life10 000 000 switching cycles/load dependentConnectionSpring clamp plug-in terminalsMounting methodDIN-rail mountable (EN 60715)Dimensions H × W × D100×45×121 mmTemperature range-25...+60 °C (storage temperature -40...+85 °C)OutputSwitching voltagemax. 250 V AC/DCSwitching current per outputmax. 6 ATotal current (STOP 0)18 A (45 °C); 15 A (55 °C); 12 A (60 °C)Total current (STOP 1)12 A (45 °C); 10 A (55 °C); 8 A (60 °C)No. of auxiliary contacts1 - (31-32)No. of alarm outputs3 - (13-14); (23-24); (33-34)No. of safety contacts3 - (13-14), (23-24), (33-34), STOP0; 2 - (47-48), (57-58), STOP1Contact materialAg Sn O, self cleaning, positively drivenCommercial datacountry of originDEcustoms tariff number85364900EAN4048879367592eClass27371819Packaging unit1 |
| Número de salidas de alarma | 3 - (13-14); (23-24); (33-34) |
| número de arancel aduanero | 85364900 |
| Dimensiones alto × ancho × profundidad | 100×45×121 mm |
| Número de contactos de seguridad | 3 - (13-14), (23-24), (33-34), STOP0; 2 - (47-48), (57-58), STOP1 |
| Corriente total (PARADA 0) | 18 A (45 °C); 15 A (55 °C); 12 A (60 °C) |
| Corriente total (PARADA 1) | 12 A (45 °C); 10 A (55 °C); 8 A (60 °C) |
| Contactos de seguridad (STOP 0) | max. 250 V AC/8 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppression |
| Contactos de seguridad (STOP 1) | max. 250 V AC/6 A; min. 10 V AC/10 mA (resist./ind.), at suitable suppression |
| Número de contactos auxiliares | 1 - (31-32) |
| Corriente de conmutación por salida | max. 6 A |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación