| Parámetro | Valor |
|---|---|
| AWG | similar to AWG 24 |
| EAN | 4048879105330 |
| Forma | 40681 |
| Codificación | M12, A-coded |
| Blindaje | no |
| Clase electrónica | 27279218 |
| N.º de artículo: | 7050-40681-6300200 |
| Material | PUR |
| Ø exterior | 4.1 mm ±5% |
| Normas | DIN EN 61076-2-104 (M8) |
| Tipo de cable | 3 (PUR) |
| Protección | IP65 and IP67 when plugged and screwed down (EN 60529) |
| Pantalla LED | no |
| Color de la chaqueta | black |
| Número de polos | 3 |
| Tensión de prueba | 2 500 V AC |
| Velocidad de torsión | 35 cycles/min |
| Color (chaqueta) | black |
| Grupo de materiales | IEC 60664-1, category II |
| Unidad de embalaje | 1 |
| Esfuerzo de torsión | ±180°/m |
| Aislamiento de cables | PP (br, bl, bk) |
| Diámetro (núcleo) | 3 × 0.25 mm² |
| Material (alambre) | Cu wire, bare |
| Método de montaje | inserted, tightened |
| Tensión nominal | 300 V AC |
| Resistencia (núcleo) | max. 79 Ω/km (20 °C) |
| Aprobación (cable) | cRUus (AWM-Style 20549/10493); CE conform |
| Material de bloqueo | M8 (zinc die casting, matte nickel plated); M12 (PA) |
| Grado de contaminación | 3 |
| Glándula de compresión | M8 (SW9) |
| Material (junta) | FKM |
| Material (chaqueta) | PUR (UL/CSA) |
| Voltaje de funcionamiento | max. 60 V AC/DC |
| Ø exterior (chaqueta) | 4.1 mm ±5% |
| Rango de temperatura | -25...+85 °C, depending on cable quality |
| país natal | DE |
| Propiedades de la pista C | 10 Mio. |
| Peso del cable [g/m] | 26,40 |
| Material (contacto) | Copper alloy |
| resistencia térmica | flame retardant UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2 |
| Radio de curvatura (fijo) | 5 × outer Ø |
| Construcción (núcleo) | 32 × 0.1 mm (multi-strand wire class 6) |
| Tensión de sobretensión nominal | 1.5 kV |
| resistencia química | good resistance to oil, gasoline and chemicals (EN 60811-404) |
| Producto alternativo: | Product ComparisonMale 90° – female 90°MQ12 – M83-polewith cable sleevesFurther cable lengths on request. Plastic housings with good resistance against chemicals and oils. The resistance to aggressive media should be individually tested for your application. Further details on request.FormForm40681CablesNo./diameter of wires3 × 0.25 mm²Wire isolationPP (br, bl, bk)C-track properties10 Mio.Material (jacket)PUR (UL/CSA)Outer Ø4.1 mm ±5%Bend radius (moving)10 × outer ØTemperature range (fixed)-40...+80 °CTemperature range (mobile)-25...+80 °CCable identification630Cable Type3 (PUR)Approval (cable)cRUus (AWM-Style 20549/10493); CE conformCable weight [g/m]26,40Material (wire)Cu wire, bareResistor (core)max. 79 Ω/km (20 °C)Single wire Ø (core)0.1 mmConstruction (core)32 × 0.1 mm (multi-strand wire class 6)Diameter (core)3 × 0.25 mm²AWGsimilar to AWG 24Material (wire isolation)PPMaterial property (wire isolation)CFC-, halogen-, cadmium-, silicone- and lead-freeShore hardness (wire isolation)70 ±5 DWire-Ø incl. isolation1.25 mm ±5%Color/numbering of wiresbr, bk, blStranding combination3 wires twistedShieldnoMaterial (jacket)PURMaterial property (jacket)CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistantShore hardness (jacket)90 ±5 AOuter-Ø (jacket)4.1 mm ±5%Color (jacket)blackchemical resistancegood resistance to oil, gasoline and chemicals (EN 60811-404)thermal resistanceflame retardant UL 1581 VW1 / CSA FT1 / IEC 60332-1, IEC 60332-2-2Nominal voltage300 V ACTest voltage2 500 V ACCurrent load capacityto DIN VDE 0298-4Temperature range (fixed)-40...+80 °C, (+90 °C at max. 10 000 operating hours)Temperature range (mobile)-25...+80 °C, (+90 °C at max. 10 000 operating hours)Bend radius (fixed)5 × outer ØBend radius (moving)10 × outer ØNo. of bending cycles (C-track)max. 10 Mio. (25 °C)Travel speed (C-track)max. 3 m/sAcceleration (C-track)max. 10 m/s²Torsion stress±180°/mNo. of torsion cyclesmax. 2 Mio. (25 °C)Torsion speed35 cycles/minJacket ColorblackTechnical DataOperating voltagemax. 60 V AC/DCRated surge voltage1.5 kVOperating current per contactmax. 4 ANo. of poles3Material groupIEC 60664-1, category IICodingM12, A-codedLED displaynoCompression glandM8 (SW9)ProtectionIP65 and IP67 when plugged and screwed down (EN 60529)MaterialPURLocking materialM8 (zinc die casting, matte nickel plated); M12 (PA)suitable for corrugated tube (internal Ø)M12 (10 mm); M8 (6.5 mm)General dataStandardsDIN EN 61076-2-104 (M8)Mounting methodinserted, tightenedMaterial (contact)Copper alloyMaterial (contact surface)AuMaterial (gasket)FKMPollution Degree3Temperature range-25...+85 °C, depending on cable qualityCommercial datacountry of originDEcustoms tariff number85444290EAN4048879105330eClass27279218Packaging unit1 |
| Radio de curvatura (móvil) | 10 × outer Ø |
| Identificación de cables | 630 |
| Capacidad de carga actual | to DIN VDE 0298-4 |
| Número de ciclos de torsión | max. 2 Mio. (25 °C) |
| Número/diámetro de los cables | 3 × 0.25 mm² |
| Ø de un solo cable (núcleo) | 0.1 mm |
| Combinación de trenzados | 3 wires twisted |
| número de arancel aduanero | 85444290 |
| Aceleración (vía C) | max. 10 m/s² |
| Velocidad de desplazamiento (vía C) | max. 3 m/s |
| Dureza Shore (chaqueta) | 90 ±5 A |
| Ø del cable incl. aislamiento | 1.25 mm ±5% |
| Color/numeración de los cables | br, bk, bl |
| Material (aislamiento del cable) | PP |
| Rango de temperatura (fijo) | -40...+80 °C |
| Material (superficie de contacto) | Au |
| Propiedad del material (cubierta) | CFC-, halogen-, cadmium-, silicone- and lead-free, matt, low-adhesion, machine easy to process, abrasion-resistant, hydrolysis and microbial resistant |
| Rango de temperatura (móvil) | -25...+80 °C |
| Corriente de funcionamiento por contacto | max. 4 A |
| Número de ciclos de plegado (vía C) | max. 10 Mio. (25 °C) |
| Dureza Shore (aislamiento del cable) | 70 ±5 D |
| Propiedad del material (aislamiento del cable) | CFC-, halogen-, cadmium-, silicone- and lead-free |
| Adecuado para tubo corrugado (Ø interior) | M12 (10 mm); M8 (6.5 mm) |