Especificaciones técnicas

ParámetroValor
EAN4001869528557
Código postal ÚnicoNot available
ETIM5
Comisión de Seguridad Nacional de las Naciones Unidas15
Clase electrónica6
● 50 HzYes
Código de grupoP310
net weight544 g
● amperímetroNo
Confirmación
Fecha: 5/6/2022
Factor metalNone
Grupo de productos5522
Clase de productoB: return restricted, please contact your Siemens partner/contact
Unidad de cantidad1 Piece
● voltímetroNo
● vatímetroYes
Código de mercancía85389091
Familia de productos7KT PAC1200 Measuring Devices
Peso neto (kg)1,683 Kg
País natalGermany
● contador de pulsosNo
LKZ_FDB/ID de catálogoLV10
Cantidad de embalaje1
nombre de marca del productoSENTRON
Dimensiones del embalaje410,00 x 420,00 x 210,00
Descripción del ProductoStarter kit 18 2x 9 sensor bars incl. 18 and 1x data manager
precisión de mediciónTotal accuracy +/-2% (of full-scale value / class 2)
designación del producto7KT PAC1200
idoneidad para el uso
● medidor de frecuenciaYes
Voltímetro (EF006560)false
diseño del producto2x9 with system, 40 A
Amperímetro (EF006555)false
Ciclo de vida del producto (PLM)PM300:Active Product
Aprobación general de productosother
Contador de pulsos (EF006559)false
designación del tipo de productoStarter kit
● medidor de potencia reactivaYes
Reglamento de control de las exportacionesAL : N / ECCN : N
Medidor de frecuencia (EF006558)true
Plazo de entrega estándar ex-fábrica5 Day/Days
Recargo por Materias PrimasNone
Medidor de potencia ciego (EF006556)true
Unidad de medida del tamaño del paqueteMM
frecuencia de línea / valor nominal
Número de unidades de ancho modular4
corriente / en la salida / valor nominal5 A
● instrumento de medición de revolucionesNo
Número de artículo (Número de mercado)7KT1222
Obligación de recogida de RAEE (2012/19/UE)Yes
Con medidor de velocidad de rotación (EF006557)false
corriente variable medida / valor nominal63 A
Dispositivo de medición de potencia efectiva (EF006561)true
Grupo de precios específico de la región / Grupo de precios de la sede15C / 1BK
Aprobación general del productoOtroConfirmaciónVariosGeneral Product Approval
Cumplimiento de las restricciones de sustancias según la directiva RoHSSince: 15.12.2015
REACH Art. 33 Deber de informar según la lista vigente de candidatosLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dodecachloropentacyclo[12... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™)covering any of its individual anti- and syn-isomers or any combination thereofBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium trioxi... CAS-No. 12060-00-3 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium trioxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Diboron trioxide CAS-No. 1303-86-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Diboron trioxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Descripción del producto

SENTRON PAC 1200; STARTER KIT. INCLUDES: 2 BARS OF 9 SENSORS, 18 SENSORS OF 40 A AND A DATA MANAGER. Cancelations and returns limited. Consult conditions.
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Detalles técnicos

Confirmation

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación