| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Producto | FP7 High-speed Counter Units |
| Número de pieza | AFP7HSC2T |
| Nombre del producto | FP7 High-speed Counter |
| Número de producto | AFP7HSC2T |
| Entrada:Método de aislamiento | Photocoupler insulation |
| Entrada: Voltaje de entrada nominal | 12 to 24 V DC / 3.5 to 5 V DC |
| Función de conteo:Tipo de contador | Linear counter / Ring counter |
| Función de conteo: E/S externa | Control signal input: 4 points (2 points/ch), External output: 4 points (2 points/ch) |
| Función de conteo: Señal de entrada | Phases A, B and Z |
| Entrada: Impedancia de entrada: 5 V CC | 390 Ohm (5 V DC) approx. |
| Función de conteo: Rango de conteo | Signed 32-bit (-2,147,483,648 to +2,147,483,647) |
| Entrada: Impedancia de entrada: 24 V CC | 3.0 kOhm approx. |
| Función de conteo: Número de contadores | 2ch |
| Entrada: Rango de voltaje de uso: 5 V CC | 3.5 to 5.25 V DC |
| Otras funciones: Función de captura | Acquires the current count value from the edges of input signals, and stores it in the capture 0 register or capture 1 register. The value of the specified capture register will be overwritten by a new value and the old value will be discarded every time a counter value is captured. |
| Función de conteo: Tipo de entrada de contador | Individual input (Phases A and B): 1 multiple, 2-multipleDirection discrimination input: 1 multiple, 2-multiple2-phase input: 1 multiple, 2-multiple, 4-multiple |
| Entrada: Ajuste de la constante de tiempo de entrada | None, 0.1 micro s, 0.2 micro s, 0.5 micro s, 1.0 micro s, 2.0 micro s and 10.0 micro s |
| Entrada:Rango de voltaje de uso:24 V CC | 10.8 to 26.4 V DC |
| Función de conteo: Frecuencia de entrada máxima | 4 MHz / 8 MHz for individual input (phases A and B) (Duty ratio 50 plus or minus 10 %), 4 MHz / 8 MHz for direction discrimination input (Duty ratio 50 plus or minus 10 %), 4 MHz / 8 MHz /16 MHz for 2-phase input (Duty ratio 50 plus or minus 10 %, Phase shifting below 5 %) |
| Otras funciones: Función de entrada de interrupción | Available (2 points/ch, Max. 8 points/unit)(Note) The interrupt input function can be used for 8 points per unit and for a maximum of 8 units (max. 64 points) in the whole system. However, the entire scan time slows down as more interrupt programs are used. Minimize the use of interrupt programs.(Note) The priority order for interrupt inputs is as follows; In a unit, from the smallest interrupt bit. In the whole system, from the smallest unit number. |
| Entrada: Voltaje mínimo de encendido / Corriente mínima de encendido: 5 V CC | 3.0 V DC / 4 mA |
| Función de comparación: Función de coincidencia del valor objetivo | Depending on the count direction, sets or resets the output when the counter value reaches the target value. |
| Entrada: Tensión mínima de encendido / Corriente mínima de encendido: 24 V CC | 10 V DC / 4 mA |
| Entrada: Voltaje máximo de apagado / Corriente máxima de apagado: 5 V CC | 1.0 V DC / 0.5 mA |
| Salida externa: Función de salida del resultado de la comparación | Outputs the result of comparison function. |
| Entrada: Voltaje máximo de apagado / Corriente máxima de apagado: 24 V CC | 2.0 V DC / 2 mA |
| Función de medición: Función de medición de frecuencia | Measures the intervals between the variations of count values, and calculates the frequency. |