| Parámetro | Valor |
|---|---|
| -10 °C ... 70 °C (flexible installation) | |
| rojo | D-SUB15 (8) = D-SUB15 (8) |
| azul | D-SUB15 (7) = D-SUB15 (7) |
| gris | D-SUB15 (5) = D-SUB15 (5) |
| rosa | D-SUB15 (6) = D-SUB15 (6) |
| Paso | 2.74 mm |
| negro | D-SUB15 (9) = D-SUB15 (9) |
| marrón | D-SUB15 (2) = D-SUB15 (2) |
| verde | D-SUB15 (3) = D-SUB15 (3) |
| blanco | D-SUB15 (1) = D-SUB15 (1) |
| violeta | D-SUB15 (10) = D-SUB15 (10) |
| amarillo | D-SUB15 (4) = D-SUB15 (4) |
| Altitud | ≤ 2000 m |
| Blindado | yes |
| rojo-azul | D-SUB15 (12) = D-SUB15 (12) |
| gris rosado | D-SUB15 (11) = D-SUB15 (11) |
| Tipo de cable | 15X0.25 [PVC] |
| marrón verdoso | D-SUB15 (14) = D-SUB15 (14) |
| blanco-verde | D-SUB15 (13) = D-SUB15 (13) |
| Longitud del cable | 1.5 m |
| Libre de halógenos | no |
| Tipo de producto | System cable |
| Rosca de tornillo | UNC 4-40 |
| Estilo UL AWM | 2464/1061 |
| blanco-amarillo | D-SUB15 (15) = D-SUB15 (15) |
| Tipo de conductor | Assembled shielded round cable |
| Línea de señal AWG | 24 |
| Revisión del artículo | 04 |
| Resistencia del cable | ≤ 80 Ω/km (at 20 °C) |
| Resistencia a las llamas | IEC 60332-1-2 (raw cable) |
| Método de conexión | D-SUB socket strip |
| Resistencia al aceite | can withstand occasional splashes (raw cable) |
| Par de apriete | 0.2 Nm |
| Material conductor | Bare Cu litz wires |
| Actual (por ruta) | ≤ 2 A (Uncoiled, see derating) |
| Notas sobre el funcionamiento | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Número de puestos | 15 |
| Grado de protección | IP20 |
| Resistencia de aislamiento | ≥ 20 MΩ*km (at 20 °C) |
| Número de conexiones | 1 |
| Vaina externa, color | gray |
| Modo de funcionamiento nominal | 100% operating factor |
| Voltaje de funcionamiento (CA) | ≤ 30 V AC |
| Voltaje de funcionamiento (CC) | ≤ 60 V DC |
| Material de la funda exterior | Semi-rigid PVC |
| Sección transversal del conductor | 15x 0.25 mm² |
| Diámetro externo del cable | 7.90 mm ±0.5 mm |
| Ciclos de inserción/retiro | > 200 |
| Diámetro del cable incluido el aislamiento | 1.2 mm ±0.05 mm |
| Temperatura ambiente (funcionamiento) | -40 °C ... 70 °C (fixed installation) |
| Línea de señal de estructura del conductor | 14x 0.15 mm |
| Capacidad de carga dinámica (flexión) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Conexión según norma | IEC 60807-2 |
| Temperatura ambiente (almacenamiento/transporte) | -40 °C ... 80 °C |
| Radio de curvatura más pequeño, instalación fija | 67 mm |
| Grado de protección (Ubicación de la instalación) | ≥ IP54 (Installation location) |
| Radio de curvatura mínimo, instalación móvil | 126 mm |