Horario de atención: Lunes a Viernes 9:00-18:00
EX-L211-C5 - EX-L211-C5 PANASONIC Laser Trough beam, 1m, spot 6x4mm, NPN, cable 5m
En stock Producto destacado

EX-L211-C5

EX-L211-C5 PANASONIC Laser Trough beam, 1m, spot 6x4mm, NPN, cable 5m

$0.00USD
4304 en stock
Especificaciones clave
Artículo:Specifications
Cable:0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong
Producción:NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
Detalles:Thru-beam type
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
Cable0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong
ProducciónNPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
DetallesThru-beam type
ProductoAmplifier Built-in Ultra-compact Laser Sensor
MaterialEnclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
AccesorioMS-EXL2-2 (Mounting plate): 2 pcs.
ProtecciónIP67 (IEC)
Número de piezaEX-L211-C5
Nombre del productoAmplifier Built-in Ultra-compact Laser Sensor EX-L200
RepetibilidadPerpendicular to sensing axis: 0.05 mm0.0020 inor less
Tiempo de respuesta0.5 ms or less
Rango de detección1 m3.281 ft
Número de productoEX-L211-C5
Objeto de detecciónOpaque object of ø2 mmø0.079 inor more
Tensión de alimentación12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Extensión de cableExtension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable (thru-beam type: Total 100 m328.084 ftboth emitter and receiver).
Indicador de encendidoGreen LED (lights up when the power is ON) (incorporated on the emitter)
Humedad ambiental35 to 85 % RH, Storage: 35 to 85 % RH
Elemento emisorRed semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 390 μW, Peak emission wavelength: 655 nm0.026 mil)
Resistencia a los golpes500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Iluminancia ambientalIncandescent light: 3,000 lx or less at the light-receiving face
Temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉
Consumo actualEmitter: 10 mA or lessReceiver: 10 mA or less
Indicador de funcionamientoOrange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Indicador de estabilidadGreen LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
Ajustador de sensibilidadContinuously variable adjuster (incorporated on the receiver)
Resistencia a la vibración10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each
Resistencia de aislamiento20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Salida:Operación de salidaLight-ON / Dark-ON selectable by the output operation switching input
Soportabilidad de tensión1,000 V AC for one min. between all supply terminals connected together and enclosure
Tamaño del punto de emisión (típico)Approx. 6 × 4 mm0.236 × 0.157 in(vertical × horizontal)(at a sensing distance of 1 m)
Cumplimiento de la directiva de marcado CEEMC Directive, RoHS Directive
Salida: Protección contra cortocircuitosIncorporated (short-circuit protection / inverse polarity protection)
Objeto de detección mínimo (típico)Opaque object of ø0.3 mmø0.012 in(Note)Typical values when the sensitivity adjuster is optimally adjusted.
Repetibilidad (típica) (perpendicular al eje de detección)0.01 mm0.0004 inor less(all area)(Note)Typical values when the sensitivity adjuster is optimally adjusted.

Descripción del producto

More details
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top