| Parámetro | Valor |
|---|---|
| 134 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| MTTF | 293 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| Profundidad | 115 mm |
| Aporte | ± 2.2 kV |
| Ancho | 23 mm |
| Altura | 101 mm |
| Señal | Ethernet |
| Voltaje | 10 V |
| Altitud | ≤ 2000 m |
| Comentarios | Criterion B |
| Material | PA 6.6-FR |
| Tipo de red | Permanent line |
| Certificado | CE-compliant |
| Criterio A | Normal operating behavior within the specified limits. |
| Criterio B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Potencia de salida | ≤ 91 W (With PoL) |
| Tipo de producto | Ethernet extenders |
| Tipo de montaje | DIN rail mounting |
| Identificación | ISA-S71.04-1985 G3 Harsh Group A |
| Emisión de ruido | EN 61000-6-4, Class A, industrial area of application |
| Inmunidad al ruido | EN 55035 |
| Funciones básicas | Gigabit Ethernet extender in accordance with ITU G.9960 |
| Intensidad de campo | 10 V/m |
| Rango de frecuencia | 80 MHz ... 3 GHz (80% amplitude modulation with 1 kHz) |
| Número de canales | 1 |
| Descarga en el aire | ± 8 kV |
| Grado de contaminación | 2 |
| Longitud de pelado | 10 mm |
| Método de conexión | Push-in spring connection |
| Descarga de contacto | ± 6 kV |
| Sección transversal AWG | (converted acc. to IEC) |
| Posición de montaje | Vertical (horizontal DIN rail) |
| Consumo de energía | ≤ 7.5 W (Without PoL, without PoE) |
| Descarga indirecta | ± 6 kV |
| Circuito de protección | Overload protection, protection against polarity reversal; Internal device protection: 2x 5 AF, internal series diode |
| Velocidad de transmisión | ≤ 1000 Mbps (Depending on the quality of the data line) |
| Dibujo dimensional | |
| Protocolos soportados | Protocol-transparent for TCP/IP, IPv4, and IPv6 |
| Longitud de transmisión | < 100 m (shielded twisted pair) |
| Método de transmisión | QAM (quadrature amplitude modulation) carrier frequency method |
| Grado de protección | IP20 |
| Aislamiento eléctrico | VCC (US+GND) // Ethernet (PoE) // G.hn (without PoL) // FE |
| Potencia máxima de salida | 15 W (at ≤55°C) |
| Rango de tensión de alimentación | 18 V DC ... 57 V DC |
| Instrucciones de montaje | To allow for air circulation, mount the device freestanding, with a clearance of at least one centimeter on all sides to other devices. |
| Normas/regulaciones | EN 61000-4-2 |
| Tensión nominal de alimentación | 24 V DC (Without PoL, without PoE) |
| Velocidad de transmisión en serie | 10/100/1000 Mbps |
| Compatibilidad electromagnética | Conformance with EMC Directive 2014/30/EU |
| Temperatura ambiente (funcionamiento) | -40 °C ... 60 °C (Free standing, without PoE) |
| Humedad admisible (funcionamiento) | 10 % ... 95 % (non-condensing) |
| Punto terminal/de un solo cable, flexible | 0.2 mm² ... 2.5 mm² |
| Clasificación de inflamabilidad según UL 94 | V0 |
| Conductor único/punto terminal, rígido | 0.2 mm² ... 2.5 mm² |
| Temperatura ambiente (almacenamiento/transporte) | -40 °C ... 85 °C |
| Sección transversal del conductor flexible [AWG] | 24 ... 16 |
| Humedad admisible (almacenamiento/transporte) | 10 % ... 95 % (non-condensing) |
| Interfaz de datos de tensión de prueba/fuente de alimentación | 1.5 kV AC (50 Hz, 1 min.) |
| Sección transversal del conductor, flexible, con casquillo, con manguito de plástico | 0.2 mm² ... 2.5 mm² |
| Sección transversal del conductor flexible, con casquillo sin manguito de plástico | 0.2 mm² ... 2.5 mm² |
| 2 conductores de igual sección, flexibles, con casquillo TWIN con funda de plástico | 0.5 mm² ... 1.5 mm² |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación