| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Peso | Net weight: 50 g approx., Gross weight: 115 g approx. |
| Detalles | Resin body type |
| Mostrar | 4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Producto | Integrated Display Type Digital Flow Sensor |
| Material | Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber |
| Linealidad | Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side) |
| Tamaño del puerto | ø4 ø0.157 push-in |
| Protección | IP40 (IEC) |
| Accesorios | CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc. |
| Número de pieza | FM-214-4 |
| Longitud del cable | Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. |
| Nombre del producto | Integrated Display Type Digital Flow Sensor FM-200 |
| Repetibilidad | Within ±1 % F.S. |
| Entrada externa | ON voltage: 0 to +0.4 VOFF voltage: +5 V to +V, or openInput time: 80 ms or more |
| Número de producto | FM-214-4 |
| Tensión de alimentación | 12 to 24 V DC ± 10 % Ripple P-P10 % or less |
| Humedad ambiental | 35 to 90 % RH, Storage: 35 to 90 % RH |
| Fluido aplicable | Clean air, compressed air, nitrogen gas(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2. |
| Resistencia a los golpes | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Método de conexión | Connector |
| Resultados comparativos | NPN open-collector transistor・Maximum sink current: 50 mA or less・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)・Residual voltage: 2.4 V or less (at 50 mA sink current) |
| Puesta a tierra del envolvente | Floating(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor. |
| Temperatura ambiente | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ |
| Consumo actual | Normal mode: 60 mA or less, ECO mode: 40 mA or less |
| Caudal a escala completa | 10 ℓ/min.(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa). |
| Rango de presión nominal | -0.09 to +0.7 MPa |
| Resistencia a la vibración | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or 49 m/s2max. acceleration, in X, Y and Z directions for two hours each |
| Salida de voltaje analógica | Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.[Refer to "Analog voltage output" for more details.] |
| Resistencia de aislamiento | 10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type) |
| Rango de garantía de precisión | Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.One-side direction : +3 to +100 % F.S.(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted. |
| Características de presión | Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side) |
| Soportabilidad de tensión | 1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type) |
| Soportabilidad a la presión | 1 MPa |
| Valor integrado especificado | 0.1 ℓ |
| Características de temperatura | Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range) |
| Salida comparativa: Histéresis | Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit) |
| Cumplimiento de la directiva de marcado CE | EMC Directive, RoHS Directive |
| Salida comparativa:Modos de salida | Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode |
| Caudal instantáneo:Rango de visualización | -11 to +11 ℓ/min.(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.). |
| Resultado comparativo: Tiempo de respuesta | 50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation |
| Caudal integrado:Rango de visualización | ±99999.99 ℓ(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.). |
| Salida comparativa: Protección contra cortocircuitos | Incorporated |
| Caudal instantáneo:Configuración y resolución de visualización | 0.01 ℓ/min. |
| Caudal integrado:Configuración y resolución de visualización | 0.01 ℓ |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación