Horario de atención: Lunes a Viernes 9:00-18:00
HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
En stock Producto destacado

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46USD
326 en stock
Especificaciones clave
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Tipo:D7
Pruebas:DIN VDE 0627/86
Ancho:21 mm
Información del proveedor
Productos: 0
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
TipoD7
PruebasDIN VDE 0627/86
Ancho21 mm
Altura34.8 mm
Longitud21 mm
SerieHC-HS
Generalfor HC-D7 housing, axial connection 2.0 mm, Allen key
SolicitudPower
Tipo de productoContact insert with a fixed no. of positions
Nota de montajeTo ensure correct use, installation in housing with IP54 protection or better is required
Corriente nominal40 A
Revisión del artículo04
Diámetro de contacto4 mm
Material de contactoCopper alloy
Enchufe hexagonalSW2,0
Numeración de contactos1 - 2
Par de apriete0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Perfil de conexión2+PE
Grado de contaminación3
Dibujo dimensional
Número de puestos2
Tensión de sobretensión nominal6 kV
Categoría de sobretensiónIII
Tecnología de conexiónAxial screw connection
Tipo de material de contactoturned
Número de contactos de potencia2
Tensión nominal (III/3)400 V
Sección transversal del conductor4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
Material portador de contactosPC
Material de la superficie de contactoAg
Ciclos de inserción/retiro≥ 500
Sección transversal de conexión AWG10 ... 8
Temperatura ambiente (funcionamiento)-40 °C ... 125 °C (including heating up of contacts)
Conexión según normaIEC / EN
Normas de construcción y pruebasDIN VDE 0627/86
Clasificación de inflamabilidad según UL 94V0
Longitud de pelado del cable individual8 mm +1 mm

Descripción del producto

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top