| Parámetro | Valor |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. | |
| Tipo | D7 |
| Pruebas | DIN VDE 0627/86 |
| Ancho | 21 mm |
| Altura | 34.8 mm |
| Longitud | 21 mm |
| Serie | HC-HS |
| General | for HC-D7 housing, axial connection 2.0 mm, Allen key |
| Solicitud | Power |
| Tipo de producto | Contact insert with a fixed no. of positions |
| Nota de montaje | To ensure correct use, installation in housing with IP54 protection or better is required |
| Corriente nominal | 40 A |
| Revisión del artículo | 04 |
| Diámetro de contacto | 4 mm |
| Material de contacto | Copper alloy |
| Enchufe hexagonal | SW2,0 |
| Numeración de contactos | 1 - 2 |
| Par de apriete | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |
| Perfil de conexión | 2+PE |
| Grado de contaminación | 3 |
| Dibujo dimensional | |
| Número de puestos | 2 |
| Tensión de sobretensión nominal | 6 kV |
| Categoría de sobretensión | III |
| Tecnología de conexión | Axial screw connection |
| Tipo de material de contacto | turned |
| Número de contactos de potencia | 2 |
| Tensión nominal (III/3) | 400 V |
| Sección transversal del conductor | 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Material portador de contactos | PC |
| Material de la superficie de contacto | Ag |
| Ciclos de inserción/retiro | ≥ 500 |
| Sección transversal de conexión AWG | 10 ... 8 |
| Temperatura ambiente (funcionamiento) | -40 °C ... 125 °C (including heating up of contacts) |
| Conexión según norma | IEC / EN |
| Normas de construcción y pruebas | DIN VDE 0627/86 |
| Clasificación de inflamabilidad según UL 94 | V0 |
| Longitud de pelado del cable individual | 8 mm +1 mm |