HC-K 6/12-ESTS - HC-K 6/12-ESTS 1636350 PHOENIX CONTACT Contact insert
En stock Producto destacado

HC-K 6/12-ESTS

HC-K 6/12-ESTS 1636350 PHOENIX CONTACT Contact insert

$114.79USD
128 en stock
Especificaciones clave
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Tipo:B16
Ancho:34 mm
Altura:47.2 mm
Información del proveedor
Productos: 0
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
TipoB16
Ancho34 mm
Altura47.2 mm
Longitud84.5 mm
SerieHC-K
GeneralFor HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench
SolicitudPower/signal
Tipo de productoContact insert with a fixed no. of positions
Nota de montajeTo ensure correct use, installation in housing with IP54 protection or better is required
Corriente nominal40 A (power contacts)
Revisión del artículo04
Diámetro de contacto4 mm
Material de contactoCu alloy
Numeración de contactos1 - 6 (power contacts)
Hoja de destornillador0.5 x 3.5 mm (control contacts)
Par de apriete2 Nm ... 2.5 Nm (PE connection)
Perfil de conexión6+12+PE
Grado de contaminación3
Dibujo dimensional
Número de puestos18
Tensión de sobretensión nominal8 kV (power contacts)
Categoría de sobretensiónIII
Tecnología de conexiónAxial screw connection (power contacts)
Tipo de material de contactoturned
Número de contactos de potencia6
Tensión nominal (III/3)690 V
Sección transversal del conductor2.5 mm² ... 10 mm² (power contacts)
Número de contactos de control12
Material portador de contactosPC
Ciclos de inserción/retiro≥ 500
Sección transversal de conexión AWG12 ... 8 (power contacts)
Temperatura ambiente (funcionamiento)-40 °C ... 125 °C
Distancia del orificio de perforación, horizontal77.5 mm
Tensión nominal para contactos de potencia230/400 V
Clasificación de inflamabilidad según UL 94V0
Longitud de pelado del cable individual8 mm +1 mm (Power 6 mm² ... 10 mm²)
Material de la superficie de contacto, contacto de potenciaAg
Material de la superficie de contacto, contacto de controlAg

Descripción del producto

Contact insert, number of poles: 6+12+PE, size: B16, power contacts: 6, control contacts: 12, Male, Axial screw connection, 690 V, 40 A, 2.5 mm² ... 10 mm², application: Power/signal