HC-M-02-AT-M-25 - HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377
En stock Producto destacado

HC-M-02-AT-M-25

HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377

$0.00USD
3215 en stock
Especificaciones clave
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
General:For HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
Solicitud:Power
Corriente nominal:100 A
Información del proveedor
Productos: 0
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
GeneralFor HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
SolicitudPower
Corriente nominal100 A
Grado de contaminación3
Número de puestos2
Tensión de sobretensión nominal8 kV
Categoría de sobretensiónIII
Instrucciones de montajeTo ensure correct use, installation in housing with IP54 protection or better is required
Tensión nominal (III/3)1000 V
Clasificación de inflamabilidad según UL 94V0
Longitud de pelado del cable individual13 mm

Descripción del producto

Contact insert module, Pin, Axial screw connection, 1000 V, 100 A, 10 mm2 ... 25 mm2, application: Power
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año