| Parámetro | Valor |
|---|---|
| GTIN | 4046356095389 |
| Nota | Made to Order (non-returnable) |
| Clave de pedido | 1637171 |
| Página del catálogo | Page 551 (C-4-2015) |
| Unidad de embalaje | 1 pc |
| País natal | DE (Germany) |
| Número de arancel aduanero | 85366990 |
| (Condiciones ambientales) | 16 mm (40 mm²) |
| Material de contacto (General) | Copper alloy |
| Corriente nominal (Dimensiones) | 200 A |
| Ancho (Datos Comerciales Clave) | 34.2 mm |
| (Normas y Reglamentos) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Altura (Datos Comerciales Clave) | 60 mm |
| Longitud (Datos Comerciales Clave) | 29.4 mm |
| Perfil de conexión (Dimensiones) | 1 |
| Tensión de sobretensión nominal (Dimensiones) | 8 kV |
| Material portador de contactos (General) | PC |
| Material de la superficie de contacto (General) | Ag |
| Tensión nominal (III/3) (Dimensiones) | 1000 V |
| Serie (Características mecánicas) | HC-M-HS |
| Peso por pieza (sin embalaje) | 69.200 g |
| Hexágono interior (Condiciones ambientales) | WAF 5 |
| RoHS de China (normas y regulaciones) | Environmentally Friendly Use Period = 50 |
| Par de apriete (condiciones ambientales) | 8 Nm (25 mm² ... 35 mm²) |
| Conexión (Características mecánicas) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The wires should be inserted as far as they will go in the contact chamber (until the insulation touches the contact). Hold wires in position and use socket wrench to tighten. The used wire end should be cut off before connecting again. The connection screw may only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable should be mechanically intercepted at an appropriate distance from the connection point (e.g., by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. The module cannot be used simultaneously with the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers. |
| Altura mínima de la carcasa (Condiciones ambientales) | 72 mm |
| Sección transversal del conductor (condiciones ambientales) | 25 mm² ... 40 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Método de conexión (Características mecánicas) | Axial screw connection |
| Conexión según norma (datos del material) | UL |
| Grado de contaminación (Características mecánicas) | 3 |
| Ciclos de inserción/extracción (Condiciones ambientales) | ≥ 500 |
| Sección transversal de conexión AWG (Condiciones ambientales) | 3 ... 2 |
| Categoría de sobretensión (Características mecánicas) | III |
| Instrucciones de montaje (Características mecánicas) | - Use only flexible conductors,- Connection of wires with 5 mm an Allen wrench,- Housing height h ≥ 72 mm,- Connectors may only be operated without load/voltage. |
| Número de ranuras para módulos (Características mecánicas) | 2 |
| Clasificación de inflamabilidad según UL 94 (datos del material) | V0 |
| Diámetro del cable incluido el aislamiento (condiciones ambientales) | 12 mm (25 mm²) |
| Temperatura ambiente (funcionamiento) (Características eléctricas) | -40 °C ... 125 °C |
| Longitud de pelado de cada cable (condiciones ambientales) | 16 mm |
| Clasificación de inflamabilidad según UL 94 (Características mecánicas) | V0 |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación