Horario de atención: Lunes a Viernes 9:00-18:00
HLC1CM - HLC1CM HL-C1C-M PANASONIC Driver for connecting 2 sensor heads HL-C1 series
En stock Producto destacado

HLC1CM

HLC1CM HL-C1C-M PANASONIC Driver for connecting 2 sensor heads HL-C1 series

$0.00USD
3584 en stock
Especificaciones clave
Artículo:Specifications
Peso:Net weight: 300 g approx.
Detalles:Controller
Producto:Ultra High-speed Laser Displacement Sensor [CCD Style]
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
PesoNet weight: 300 g approx.
DetallesController
ProductoUltra High-speed Laser Displacement Sensor [CCD Style]
Accesorio-
Número de piezaHL-C1C-M
Salida de alarmaPhoto-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between alarm output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Longitud del cablePower line: Less than 10 m 32.808 ftSignal line: Less than 30 m 98.425 ft
Nombre del productoUltra High-speed Laser Displacement Sensor HL-C1(Discontinued)
Frecuencia de muestreoSelectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s
Funciones de retenciónSelectable from NORMAL / P-P / PEAK / VALLEY(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Número de productoHL-C1C-M
Tensión de alimentación24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Filtros digitalesHigh pass: OFF, 10 to 2,000 Hz (9 steps)Low pass: OFF, 10 to 2,000 Hz (9 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Indicadores: OSCURORed LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2)
Puesta a cero en la entradaZero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Calibración: Intervalo0.9000 to 1.1000(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Entrada de puesta a cero desactivadaZero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Calibración: Cambioplus or minus 20.0000 mm plus or minus 0.787 in(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Consumo actualWhen 1 sensor is connected: 430 mA approx.When 2 sensors are connected: 550 mA approx.
Indicadores: BRILLANTESRed LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2)
Funciones de cálculoL plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B)A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Entrada/salida en serieRS-232C
Cabezal sensor ConnectaleMaximum 2 sensor heads
Salida analógica: CorrienteOutput current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)]Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance)Load impedance: 250 Ohm or less(Note 1) The maximum analog output current will vary with load impedance.(Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
Salida analógica: VoltajeOutput voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ]Output range: -10.9 to +10.9 VOutput current: Max. 2 mA, Output impedance: 50 Ohm(Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S.
Número promedio de muestrasOFF, 2 to 32,768 times (16 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Resultados del juicio (O1, O2)Photo-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between judgment output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Indicadores: Emisión láserGreen LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission)
Características de temperaturaplus or minus 0.01 % F.S./degrees
Entrada de temporización (emisión láser)Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection.
Salida de alarma: Operación de salidaOpened when the amount of light is excessive or insufficient.
Salida de alarma: Protección contra cortocircuitosIncorporated
Resistencia ambiental: Humedad ambiente35 to 85 % RH, Storage: 35 to 85 % RH
Resistencia ambiental: Resistencia a los golpes196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each
Salidas de juicio (O1, O2): Operación de salidaOpened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.)
Resistencia ambiental: Temperatura ambiente0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Resistencia ambiental: Resistencia a la vibración10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each
Resultados del juicio (O1, O2): Categoría de utilizaciónDC-12 or DC-13
Salidas de juicio (O1, O2): Protección contra cortocircuitosIncorporated

Descripción del producto

More details
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top