| Parámetro | Valor |
|---|---|
| Nombre | RPS-400-36 |
| Estado | Recommended Model |
| Alarmas | Powerfail, Output OK |
| Formato | Open Format |
| Serie | RPS-400 |
| Aprobaciones | CE, EN60601 3rd Edition, UL |
| Potencia (W) | 252,00 |
| Subformato | 5"x3" |
| Ancho (mm) | 76.2 |
| Altura (mm) | Thirty five |
| Entrada de CA Máx. | 264,00 |
| Entrada de CA mínima | 80,00 |
| Aplicaciones | Industrial, Medical, Telecommunications |
| Fabricante | MEAN WELL |
| Tipo de producto | Power supply AC/DC |
| Aislamiento (V) | 4.000,00 |
| Voltaje de salida | 36,00 |
| Potencia máxima (W) | 403.2 |
| Conector de entrada | Plug-in |
| Frecuencia de entrada | 50 Hz, 60 Hz |
| Largo/Fondo | One hundred twenty seven |
| Descripción larga | Medical power supply in open format(open-frame).Source certified for medical applications 2x MOPP (patient protection).Open format (open-frame).Range of universal input80-264vac.47-63Hz.Output voltage36Vcc.Adjustable by potentiometer (34,2-a 37.8 Dc).Output intensity7A. Range of output current 0-7A according to demand load.Power:252W.Efficiency typical:93%.Factor Corrector, Power>0,94to 230vac and full load.Alarm output voltage correct (DC-Ok) and network failure (Power fail).Remote on / off.Auxiliary output Stand-by 5V 0.3 A.Auxiliary output 12vdc 0.5 A to power an external fan.Function of sensing to compensate the voltage drop in the cables.Consumption without load <0.5 W.Low leakage current to ground < 200µA at 264vac, and low contact current < 100µA at 264vac.Working temperature: from-30up+70 ° Cof ambient temperature. Consult the technical data sheet to see the curves of drift.Dimensions (Length x Width x Height) [mm]:127 x 76.2 x 35.3 years of warranty.Manufacturer: MEAN WELL.The series RPS-400 are power supply certified for medical use with patient protection, 2 x MOPP (means of patient protection). They have a double protection between input and output 2xMOPP and protection between input and ground 1xMOPP.Have a leakage current (contact current) is very low for a greater security in the application. Can operate with cooling by free air circulation or provide a higher power through the use of an external fan.These sources can be used for medical applications BF (body floating) with the necessary considerations of the system and for industrial applications, and information technology.Its compact size of 5" x 3" to make it suitable for applications with space limitations. |
| Conector de salida | Screw-Type |
| Tipo de entrada CA | Single-phase |
| Garantía (años) | 3,00 |
| País natal | China |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación