| Parámetro | Valor |
|---|---|
| PL | d (2A@230VAC; 1 comm. @30s)e (2A@230VAC; 1 comm. @60s)e (2A@230VAC; 1 comm. @1h)e (2A@230VAC; 1 comm. @24h)d (0,5A@230VAC; 1 comm. @30s)d (0,5A@230VAC; 1 comm. @60s)e (0,5A@230VAC; 1 comm. @1h)e (0,5A@230VAC; 1 comm. @24h) |
| CFF | 80% |
| SIL | 4 |
| PFHd | 2,08E-08 (2A@230VAC; 1 comm. @30s)1,71E-08 (2A@230VAC; 1 comm. @60s)6,588E-09 (2A@230VAC; 1 comm. @1h)6,42E-09 (2A@230VAC; 1 comm. @24h)5,03E-08 (0,5A@230VAC; 1 comm. @30s)2.80E-08 (0,5A@230VAC; 1 comm. @60s)6,76E-09 (0,5A@230VAC; 1 comm. @1h) |
| Tipo | 4 |
| Dcavg | 98,89% (2A@230VAC; 1 comm. @30s)98,78% (2A@230VAC; 1 comm. @60s)98,78% (2A@230VAC; 1 comm. @1h)96,25% (2A@230VAC; 1 comm. @24h)98,94% (0,5A@230VAC; 1 comm. @30s)98,89% (0,5A@230VAC; 1 comm. @60s)97,01% (0,5A@230VAC; 1 comm. @1h)96,28% (0,5A@23 |
| MTTFd | 25,97 (2A@230VAC; 1 comm. @30s)49,42 (2A@230VAC; 1 comm. @60s)100 (2A@230VAC; 1 comm. @1h)100 (2A@230VAC; 1 comm. @24h)13,25 (0,5A@230VAC; 1 comm. @30s)25,97 (0,5A@230VAC; 1 comm. @60s)100 (0,5A@230VAC; 1 comm. @1h)100 (0,5A@230VAC; 1 comm. @2 |
| SILCL | 4 |
| Aprobaciones | CE, cULus, TÜV |
| Dimensiones | 35 x 99 x 114,5 mm |
| Conexiones | terminals |
| Descripción | Cat. 4 Safety Module with integrated Muting function |
| Tipo de salida | 2 x relay NO (OSSD safety output)1 x NO, 100mA, 24V (System Status) |
| Utilizable con | Safety light curtains: LS2, LS4, LP4 |
| Corriente de carga | 2A @ 250V |
| Tiempo de respuesta | ≤ 20ms |
| Compatibilidad EMC | According to 2014/30/EU Directive |
| Voltaje de funcionamiento | 24Vdc ± 20% |
| Anular tiempo de espera | 15 min |
| Consumo de energía | ≤ 5W |
| Principio de función | Control unit |
| Salida de lámpara de silenciamiento | 24V - 0,5 … 5W |
| Funciones disponibles | Manual/Automatic Restart, EDM, System Status, Muting, Override |
| Grado de protección | IP20 |
| Temperatura de funcionamiento | 0°C … + 55°C |
| Longitud del cable (sensores) | ≤ 100m |
| Distancia de detección nominal | According to the sensors used:LS2 up to 12mLS4 up to 20m |
| Número máximo de sensores de silenciamiento | 2 x PNP-NO |
| Número máximo de sensores conectados | 1 x LS2/LS4 receiver |
| Longitud del cable (fuente de alimentación/salida) | ≤ 100m |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación