| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| PFHD | 3.98 × 10-9(Note) Probability of dangerous failure per hour. |
| Cable | 0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long |
| MTTFD | 100 years or more(Note) Mean time to dangerous failure. |
| Detalles | Hand protection type Min. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch) |
| Producto | Ultra-slim Light Curtain [Type 2 PLc SIL1] |
| Material | Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloyMS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) |
| Paso de viga | 20 mm0.787 in |
| Accesorios | MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No. |
| Número de pieza | SF2C-H32-P |
| Nombre del producto | Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C |
| Voltaje de potencia | 24 V DC plus or minus 20 % Ripple P-P 10 % or less |
| Tiempo de respuesta | OFF response: 20 ms or lessON response: 80 to 100 ms |
| Número de producto | SF2C-H32-P |
| Extensión de cable | Extension up to total 50m is possible for 0.3mm2or more, cable |
| Rango de operación | 0.1 to 3 m0.328 to 9.843 ft |
| Humedad ambiental | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Elemento emisor | Infrared LED (Peak emission wavelength: 850 nm0.034 mil) |
| Grado de contaminación | 3 |
| Resistencia a los golpes | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Altura de protección | 640 mm25.197 in |
| Altitud de operación | 2, 000 m6561.680 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Iluminancia ambiental | Incandescent light: 5,000 ℓx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: - 25 to +60 ℃- 13 to +140 ℉ |
| Salida de bloqueo (SSD) | - Maximum sink current: 60mA- Applied voltage: same as supply voltage (between the lockout output and +V)- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less |
| Mínimo objeto detectado | ø25 mmø0.984 inopaque object |
| Función de entrada de prueba | Incorporated |
| Salida de control (OSSD) | - Maximum source current: 200mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less |
| Número de canales de haz | 32 |
| Resistencia a la vibración | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Ángulo de apertura efectivo | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| Normas aplicables: Japón | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) |
| Cumplimiento de la directiva de marcado CE | Machinery Directive, EMC Directive, RoHS Directive |
| Normas aplicables: Europa (UE) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
| Función de prevención de interferencias | Incorporated |
| Normas aplicables: América del Norte | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. |
| Salida de bloqueo (SSD): Modo de operación | ON during normal operation, OFF during lockout(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
| Salida de control (OSSD): Modo de operación | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) |
| Función indicadora multiusos de gran tamaño | Incorporated |
| Salida de bloqueo (SSD): Circuito de protección | Incorporated |
| Salida de control (OSSD): Circuito de protección | Incorporated |
| Peso neto (Total de emisor y receptor) | 640 g approx. |
| Normas aplicables: Norma internacional | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) |
| Resistencia ambiental: Grado de protección | IP65, IP67 (IEC) |
| Consumo de corriente: Se enciende el indicador multiusos grande. | Emitter: 50 mA or lessReceiver: 45 mA or less |
| Consumo de corriente: Luces indicadoras multiusos grandes apagadas | Emitter: 35 mA or lessReceiver: 35 mA or less |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación