| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| PFHD | 1.7 × 10-9 |
| MTTFD | 100 years or more |
| Detalles | Min. sensing object ø45 mmø1.772 intype (40 mm1.575 inbeam pitch) |
| Producto | Safety Light Curtain Type 4 |
| Material | Enclosure: AluminiumUpper and lower edges: IronSensing surface: Polycarbonate / Polyester resinCap: PBT |
| Número de pieza | SF4B-A10(V2) |
| Longitud del cable | Total length up to 50 m164.042 ftis possible for both emitter and receiver, with optional mating cables(Note) The cable can be extended within 30 m98.425 ft(for emitter / receiver) when two light curtains are connected in series, within 20 m65.617 ftwhen three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m131.234 ft(for emitter / receiver). |
| Nombre del producto | Safety Light Curtain Type 4 SF4B Ver.2 |
| Voltaje de potencia | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Tiempo de respuesta | OFF response: 14 ms or less, ON response: 80 to 90 ms |
| Número de producto | SF4B-A10(V2) |
| Función de silenciamiento | Incorporated(Note) Please use 12-core cable. |
| Rango de operación | 0.3 to 9 m0.984 to 29.528 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Humedad ambiental | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Elemento emisor | Infrared LED (Peak emission wavelength: 870 nm0.034 mil) |
| Resistencia a los golpes | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Método de conexión | Connector |
| Función de anulación | Incorporated(Note) Please use 12-core cable. |
| Altura de protección | 390 mm15.354 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) |
| Función de enclavamiento | Incorporated [Manual reset / Auto reset (Note)](Note) The manual reset and auto reset are possible to be switched depending on the wiring status. |
| Funciones opcionales | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control(Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01<V2> and the SF-C14EX-01. |
| Iluminancia ambiental | Incandescent light: 3,500 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 °+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ |
| Consumo actual | Emitter: 65 mA or lessReceiver: 85 mA or less |
| Mínimo objeto detectado | ø45 mmø1.772 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed. |
| Número de canales de haz | 10 |
| Resistencia a la vibración | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Función de detención de emisiones | Incorporated |
| Ángulo de apertura efectivo | plus or minus 2.5°or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)] |
| Normas aplicables: Japón | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)(Note) PLe SIL3 compliant from production in August 2009. |
| Normas aplicables: China (GB) | GB/T 4584(Note) PLe SIL3 compliant from production in August 2009. |
| Cumplimiento de la directiva de marcado CE | Machinery Directive, EMC Directive, RoHS Directive |
| Normas aplicables: Europa (UE) | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) PLe SIL3 compliant from production in August 2009. |
| Salidas de control (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)- When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m65.617 ftlength cable) |
| Función de prevención de interferencias | Incorporated(Note) Please use 12-core cable. |
| Normas aplicables: América del Norte | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) PLe SIL3 compliant from production in August 2009. |
| Función de monitorización de dispositivos externos | Incorporated |
| Salida auxiliar (salida sin seguridad) | PNP open-collector transistor / NPN open-collector transistor (switching method)- When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m65.617 ftlength cable) |
| Peso (Total de emisor y receptor) | 810 g approx. |
| Normas aplicables:Corea del Sur (S-Mark) | S1-G-35-2005, S2-W-11-2003(Note) PLe SIL3 compliant from production in August 2009. |
| Normas aplicables: Norma internacional | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)(Note) PLe SIL3 compliant from production in August 2009. |
| Resistencia ambiental: Grado de protección | IP67 / IP65 (IEC) |
| Salidas de control (OSSD 1, OSSD 2): Modo de operación | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed. |
| Salidas de control (OSSD1, OSSD2): Circuito de protección | Incorporated |
| Salida auxiliar (salida sin seguridad): tiempo de respuesta | OFF replay: 34 ms or less, ON replay 110 ms or less |
| Salida auxiliar (salida sin seguridad): modo de funcionamiento | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). |
| Resistencia ambiental: Tensión de rigidez dieléctrica | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Altura de protección: compatible con China Press (GB/T 4584) | 360mm14.173in |
| Salida auxiliar (salida sin seguridad): circuito de protección | Incorporated |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación