Especificaciones clave
Artículo:Specifications
PFHD:3.7 × 10-9(Note) Probability of dangerous failure per hour.
Cable:0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
MTTFD:100 years or more(Note) Mean time to dangerous failure.
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
PFHD3.7 × 10-9(Note) Probability of dangerous failure per hour.
Cable0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
MTTFD100 years or more(Note) Mean time to dangerous failure.
DetallesMin. sensing object ø45 mmø1.772 in(40 mm1.575 inbeam pitch)
ProductoCompact Safety Light Curtain[Type4 PLe SIL3]
MaterialEnclosure: Polycarbonate
Paso de viga40 mm1.575 in
Accesorios-
Número de piezaSF4B-A40CA-J05
Nombre del productoCompact Safety Light Curtain[Type4 PLe SIL3] SF4B-C
Función ELCAIncorporated (reducing mutual interference automatically)
Voltaje de potencia24 V DC plus or minus 10 % Ripple P-P 10 % or less
Tiempo de respuestaOFF response: 14 ms or lessON response: 80 to 90 ms
Número de productoSF4B-A40CA-J05
Extensión de cableExtension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables
Función de silenciamientoIncorporated
Rango de operación0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver.
Humedad ambiental30 to 85 % RH, Storage: 30 to 85 % RH
Elemento emisorInfrared LED (Peak emission wavelength: 850 nm0.033 mil)
Grado de contaminación3
Resistencia a los golpes300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each
Función de anulaciónIncorporated
Altura de protección1,623.4 mm63.913 in
Función de enclavamientoIncorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Altitud de operación2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
Funciones opcionalesMuting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required.
Iluminancia ambientalIncandescent light: 3,500 liter x or less at the light-receiving face
Temperatura ambiente-10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉
Mínimo objeto detectadoø 45 mmø 1.772 inopaque object(Note) In case the blanking function is valid, the operation mode is changed.
Número de canales de haz40
Resistencia a la vibración10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each
Resistencia de aislamiento20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Función de detención de emisionesIncorporated
Silenciar la salida auxiliarNPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable)
Ángulo de apertura efectivoplus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
Normas aplicables: JapónJIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
Cumplimiento de la directiva de marcado CEMachine Directive, EMC Directive, RoHS Directive
Normas aplicables: Europa (UE)EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Salidas de control (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3 Ω or less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3 Ω or less
Normas aplicables: América del NorteANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognizedsafety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
Función de monitorización de dispositivos externosIncorporated
Salida auxiliar (salida sin seguridad)PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable)
Función indicadora multiusos de gran tamañoIncorporated
Silenciar salida auxiliar: Modo de funcionamientoWhen muting auxiliary output: ON
Normas aplicables:Corea del Sur (S-Mark)S1-G-35-2005, s2-W-11-2003
Salida auxiliar de silenciamiento: Circuito de protecciónIncorporated
Peso neto (Total de emisor y receptor)approx. 1,700 g
Normas aplicables: Norma internacionalIEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Resistencia ambiental: Grado de protecciónIP65 (IEC)
Salidas de control (OSSD 1, OSSD 2): Modo de operaciónON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change.
Salidas de control (OSSD1, OSSD2): Circuito de protecciónIncorporated
Salida auxiliar (salida sin seguridad): modo de funcionamientoOFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Resistencia ambiental: Tensión de rigidez dieléctrica1,000 V AC for one min. between all supply terminals connected together and enclosure
Salida auxiliar (salida sin seguridad): circuito de protecciónIncorporated
Consumo de corriente: Se enciende el indicador multiusos grande.Emitter: 85 mA or lessReceiver: 105 mA or less
Consumo de corriente: Luces indicadoras multiusos grandes apagadasEmitter: 75 mA or lessReceiver: 95 mA or less

Descripción del producto

More details
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top