| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| PFHD | 5.7 × 10-9(Note) Probability of dangerous failure per hour. |
| Cable | 0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long |
| MTTFD | 100 years or more(Note) Mean time to dangerous failure. |
| Detalles | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
| Producto | Compact Safety Light Curtain[Type4 PLe SIL3] |
| Material | Enclosure: Polycarbonate |
| Paso de viga | 20 mm0.787 in |
| Accesorios | SF4B-TR25 (Test rod): 1 pc. |
| Número de pieza | SF4B-H80CA-J05 |
| Nombre del producto | Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C |
| Función ELCA | Incorporated (reducing mutual interference automatically) |
| Voltaje de potencia | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Tiempo de respuesta | OFF response: 14 ms or lessON response: 80 to 90 ms |
| Número de producto | SF4B-H80CA-J05 |
| Extensión de cable | Extension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables |
| Función de silenciamiento | Incorporated |
| Rango de operación | 0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Humedad ambiental | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Elemento emisor | Infrared LED (Peak emission wavelength: 850 nm0.033 mil) |
| Grado de contaminación | 3 |
| Resistencia a los golpes | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each |
| Función de anulación | Incorporated |
| Altura de protección | 1,623.4 mm 63.913 in |
| Función de enclavamiento | Incorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| Altitud de operación | 2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Funciones opcionales | Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required. |
| Iluminancia ambiental | Incandescent light: 3,500 liter x or less at the light-receiving face |
| Temperatura ambiente | -10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉ |
| Mínimo objeto detectado | ø25 mm ø0.984 in opaque object(Note) In case the blanking function is valid, the operation mode is changed. |
| Número de canales de haz | 80 |
| Resistencia a la vibración | 10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Función de detención de emisiones | Incorporated |
| Silenciar la salida auxiliar | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable) |
| Ángulo de apertura efectivo | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| Normas aplicables: Japón | JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3) |
| Cumplimiento de la directiva de marcado CE | Machine Directive, EMC Directive, RoHS Directive |
| Normas aplicables: Europa (UE) | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Salidas de control (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less |
| Normas aplicables: América del Norte | ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognizedsafety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7 |
| Función de monitorización de dispositivos externos | Incorporated |
| Salida auxiliar (salida sin seguridad) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable) |
| Función indicadora multiusos de gran tamaño | Incorporated |
| Silenciar salida auxiliar: Modo de funcionamiento | When muting auxiliary output: ON |
| Normas aplicables:Corea del Sur (S-Mark) | S1-G-35-2005, S2-W-11-2003 |
| Salida auxiliar de silenciamiento: Circuito de protección | Incorporated |
| Peso neto (Total de emisor y receptor) | approx. 1,700 g |
| Normas aplicables: Norma internacional | IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) |
| Resistencia ambiental: Grado de protección | IP65 (IEC) |
| Salidas de control (OSSD 1, OSSD 2): Modo de operación | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change. |
| Salidas de control (OSSD1, OSSD2): Circuito de protección | Incorporated |
| Salida auxiliar (salida sin seguridad): modo de funcionamiento | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.) |
| Resistencia ambiental: Tensión de rigidez dieléctrica | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Salida auxiliar (salida sin seguridad): circuito de protección | Incorporated |
| Consumo de corriente: Se enciende el indicador multiusos grande. | Emitter: 105 mA or lessReceiver: 140 mA or less |
| Consumo de corriente: Luces indicadoras multiusos grandes apagadas | Emitter: 95 mA or lessReceiver: 130 mA or less |
Especificaciones técnicas y datos de rendimiento