Especificaciones clave
Artículo:Specifications
PFHD:3.69×10-9
MTTFD:318 years or more
Observación:Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
PFHD3.69×10-9
MTTFD318 years or more
ObservaciónWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
DetallesMin. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch)
ProductoSafety Light Curtain [Type 4 PLe SIL3]
MaterialEnclosure : Aluminum, Detection surface : Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap : Nylon
AccesoriosSF4B-TR25 (test rod) : 1 pc.
Número de piezaSF4D-H80-01
Nombre del productoCompact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D
Estado de seguridadControl output (OSSD 1 / 2) OFF state
Voltaje de potencia24 V DC+20-30 %Ripple P-P 10 % or less (excluding voltage drop due to cable)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline.
Número de productoSF4D-H80-01
Tipo de subsistemaType B (IEC 61508-2)
Extensión de cableTotal length of emitter / receiver can be extended up to 70 m229.659 fteach using optional mating cable (including the lengthof series mating cables)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline.
Función de silenciamientoIncorporated (12-core cable)
Rango de operaciónShort mode : 0.2 to 9 m0.656 to 29.528 ftLong mode : 0.8 to 15 m2.625 to 49.213 ft(selectable by DIP switch)(Note): The operating range is the possible setting distance between the emitter and the receiver.
Humedad ambiental30 to 85 % RH, Storage : 30 to 95 % RH
Elemento emisorInfrared LED (peak emission wavelength : 850 nm0.0335 mil)
Grado de contaminación3
Resistencia a los golpes300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each
Método de conexiónBy connector
Función de anulaciónIncorporated (12-core cable)
Altura de protección1,590 mm62.598 in(Note): When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.
Función de enclavamientoIncorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable)
Altitud de operación2,000 m6,561.68 ftor less(Note): Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
Funciones opcionalesOptional functions cannot be used when SF4D-□-01 is used.
Iluminancia ambientalIncandescent light : 5,000 ℓx or less at the light-receiving surface
Temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage : -25 to +60 ℃-13 to +140 ℉
Consumo actualEmitter : 120 mA or lessReceiver : 150 mA or less
Mínimo objeto detectadoø25 mmø0.984 inopaque object(Note): When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance.
Función de ahorro de energíaIncorporated
Función de entrada de pruebaIncorporated
Número de canales de haz80
Resistencia a la vibración10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each
Tiempo de respuesta ante fallosWithin response time (OFF response)
Resistencia de aislamiento20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure
Método de sincronizaciónLine synchronization / optical synchronization (selectable by DIP switch)
Ángulo de apertura efectivo±2.5° or less at a sensing range of 3 m9.843 ftor longer (based on IEC 61496-2)
Función de liberación de bloqueoIncorporated
T1 (intervalo de prueba)20 years
Normas aplicables: JapónJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
SFF (Fracción de fallo seguro)99%
Función de indicador de aplicaciónIncorporated (only the receiver lights up when optical synchronization is used)
HFT (Tolerancia a fallos de hardware)1
Normas aplicables: China (GB)GB/T 4584
Cumplimiento de la directiva de marcado CEMachinery Directive, EMC Directive, RoHS Directive
Normas aplicables: Europa (UE)EN 61496-1/2 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 55011, EN 61000-6-2, EN 50178
Salidas de control (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 350 mA・Applied voltage : Same as supply voltage(between control output and +V)・Residual voltage : 2 V or less (source current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less<NPN output selected>・Maximum sink current : 350 mA・Applied voltage : Same as supply voltage(between control output and 0 V)・Residual voltage : 2 V or less (sink current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less
Función de prevención de interferencias<Not connected in series/parallel>・Line synchronization : 2 units or less (auto)・Optical synchronization : 2 units or less (selectable by DIP switch)<Connected in series/parallel>・Series connection : 5 units or less (total number of beam channels 256 or less)・Parallel connection : 3 units or less (total number of beam channels 192 or less)(Note)・Series / parallel connection mixed : 5 units or less (total number of beam channels 144 or less)(Note)(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Normas aplicables: América del NorteANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2
Función de monitorización de dispositivos externosIncorporated (8-core cable or 12-core cable)
Peso (Total de emisor y receptor)4,000g approx.
Salida auxiliar (AUX) (salida sin seguridad)PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and +V)・Residual voltage : 2 V or less (source current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)<NPN output selected>・Maximum sink current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and 0 V)・Residual voltage : 2 V or less (sink current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)
Normas aplicables: Norma internacionalIEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Salida de control (OSSD 1, OSSD 2): Tiempo de respuestaOFF response : 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel)(Note 1)ON response : 50 ms or less (Note 2)(Note 3)(Note 1): For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times.(Note 2): Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms.(Note 3): When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec.
Resistencia ambiental: Grado de protecciónIP67, IP65 (IEC), NEMA Type 13 (NEMA 250)
Salidas de control (OSSD 1, OSSD 2): Modo de operaciónON when all beams are received, OFF when one or more beams are blocked(Also OFF when internal sensor error or synchronization signal error occurs)(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Salidas de control (OSSD1, OSSD2): Circuito de protecciónIncorporated
Resistencia ambiental: Tensión de rigidez dieléctrica1,000 V AC for one minute, between all supply terminals connected together and enclosure
Salida auxiliar (AUX) (salida sin seguridad): tiempo de respuestaOFF response : 60 ms or less, ON response : 60 ms or less
Salida auxiliar (AUX) (salida sin seguridad): modo de funcionamientoControl output ON : OFF, Control output OFF : ON(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Salida auxiliar (AUX) (salida sin seguridad): circuito de protecciónIncorporated
Altura de protección: Cuando se utiliza como equipo de seguridad para máquinas de prensado chinas o cuando se utiliza para máquinas de prensado japonesas o cizallas de papel.1,580 mm62.205 in(Note): When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.

Descripción del producto

More details
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top