| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Peso | Net weight: 1 kg approx. |
| Detalles | Robust type control unit |
| Producto | Exclusive Control Unit for Safety Light Curtain |
| Clasificación del fusible | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
| Número de pieza | SF-C12 |
| Nombre del producto | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Voltaje de potencia | 24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) |
| Tiempo de respuesta | 14 ms or less |
| Salida de seguridad | NO contact × 2 (13-14, 23-24) |
| Número de producto | SF-C12 |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Grado de contaminación | 2 |
| Salidas auxiliares | Safety relay contact (NC contact) × 1 (31-32) (Related to enabling path) |
| Material de cerramiento | Die-cast aluminium |
| Temperatura ambiente | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| Terminal de conexión | European terminal |
| Consumo actual | 100 mA or less (without light curtain) |
| Categoría de sobretensión | III |
| Resistencia a la vibración | Resistance 10 to 55 Hz frequency, 0.75 mm0.030 inamplitudein X, Y, and Z directions for two hours each |
| Función de borde de salida | Incorporated |
| Indicadores:Fallo (FAULT) | Orange LED (lights up when two safety light curtain input polarity selection switch settings are different) |
| Normas aplicables: Japón | JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), |
| Función de selección de polaridad | Incorporated (Sliding switch allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
| Indicadores: Fuente de alimentación (Ui) | Green LED (lights up when the power is ON) |
| Indicadores: Salida de seguridad [OUT] | Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.) |
| Cumplimiento de la directiva de marcado CE | Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive |
| Función de monitorización de relé externo | Incorporated(Note:Terminals for utilizing the functions of theSF4B/SF4B-Gseries are available.) |
| Normas aplicables: Europa (UE) | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe)(Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| Salida de seguridad: Resistencia de contacto | 50 mOhm or less (initial value) |
| Cortinas de luz de seguridad conectables | SF4B / SF4B-Gseries |
| Indicadores: Interbloqueo (INTER_LOCK) | - |
| Salida de seguridad: Vida útil eléctrica | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Salida de seguridad: Vida útil mecánica | 10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| Normas aplicables: América del Norte | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| Salida de seguridad:Categoría de aplicación | AC-15, DC-13 (IEC 60947-5-1) |
| Salida auxiliar de semiconductor (AUX) | - |
| Retardo de recogida (reinicio automático / reinicio manual) | 30 ms or less / 30 ms or less |
| Salida de seguridad:Material de contacto/contactos | AgNiO + 0.2 micro m 0.008 mil Au plating, self cleaning, positively driven |
| Normas aplicables: Norma internacional | IEC 61496-1 (Type 4) |
| Salida de seguridad: Fusible de protección de contacto nominal | 3 A (slow blow) |
| Resistencia ambiental: Grado de protección | IP65 |
| Salida auxiliar: Fusible de protección de contacto nominal | 3 A (slow blow) |
| Salida auxiliar: Tensión/corriente nominal de funcionamiento | 30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC) |
| Salida auxiliar de semiconductor (AUX): Operación de salida | - |
| Salida de seguridad: Tensión nominal de funcionamiento (Ue) / Corriente nominal de funcionamiento (le) | 1 A / 24 V DC, resistive load (For inductive load, during contact protection) Min. applicable load: 15 mA (at 24 V DC) |
Especificaciones técnicas y datos de rendimiento