| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| PFHD | 1.66 × 10-10(Note:Probability of dangerous failure per hour) |
| MTTFD | 100 years or more(Note:Mean time to dangerous failure (in years)) |
| Peso | Net weight: 250 g approx. |
| Detalles | Applicantion expansion unit for the SF4B series |
| Producto | Exclusive Control Unit for Safety Light Curtain |
| Material | Enclosure: ABS |
| Número de pieza | SF-C14EX |
| Nombre del producto | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Voltaje de potencia | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Número de producto | SF-C14EX |
| Humedad ambiental | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Categoría de control | ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards |
| Resistencia a los golpes | 30 G acceleration in X, Y and Z directions three times each |
| Salida de lámpara de silenciamiento | Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) |
| Temperatura ambiente | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉ |
| Terminal de conexión | Detachable spring-cage terminal |
| Consumo actual | 0.2 A or less (Excluding Safety light curtain and other external connecting device) |
| Resistencia a la vibración | 10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Normas aplicables: Japón | JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe) |
| Cumplimiento de la directiva de marcado CE | Machinery Directive, EMC Directive, RoHS Directive |
| Normas aplicables: Europa (UE) | EN 55011, EN ISO 13849-1 (Category 4, PLe) |
| Cortinas de luz de seguridad conectables | SF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.) |
| Normas aplicables: América del Norte | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
| Salida de lámpara de silenciamiento: Circuito de protección | Incorporated |
| Normas aplicables: Norma internacional | IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe) |
| Resistencia ambiental: Grado de protección | Enclosure: IP40Terminal: IP20 |
| Resistencia ambiental: Tensión de rigidez dieléctrica | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Salidas de seguridad (Salida de seguridad 1, Salida de seguridad 2, Salida de seguridad 3) | PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current) |
| Salidas de seguridad (Salida de seguridad 1, Salida de seguridad 2, Salida de seguridad 3): Tiempo de respuesta | OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3. |
| Salidas auxiliares (Salida auxiliar 1, Salida auxiliar 2, Salida auxiliar 3, Salida auxiliar 4) | PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current) |
| Salidas de seguridad (Salida de seguridad 1, Salida de seguridad 2, Salida de seguridad 3): Modo de operación (Operación de salida) | Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid |
| Salidas de seguridad (Salida de seguridad 1, Salida de seguridad 2, Salida de seguridad 3): Circuito de protección (Protección contra cortocircuito) | Incorporated |
| Salidas auxiliares (Salida auxiliar 1, Salida auxiliar 2, Salida auxiliar 3, Salida auxiliar 4): Modo de operación (Operación de salida) | Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.) |
| Salidas auxiliares (Salida auxiliar 1, Salida auxiliar 2, Salida auxiliar 3, Salida auxiliar 4): Circuito de protección (Protección contra cortocircuitos) | Incorporated |
Especificaciones técnicas y datos de rendimiento