| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Peso | TH-12: 120 g approx.TH-C2P: 140 g approx. |
| Detalles | Sensor head + Controller |
| Producto | Hot Melt Glue Detector TH |
| Material | TH-12(Sensor head): Enclosure: Polycarbonate, Indicator: Polycarbonate, Lens: SiliconeTH-C2P(Controller): Enclosure: Heat-resistant ABS, Terminal cover: Heat-resistant ABS, Front cover: Polycarbonate |
| Accesorios | MS-TH-2 (Sensor head mounting bracket): 1 set, TH-B2 (Heat shield): 1 pc., OS-TH12 (Slit mask): 1 pc. |
| Número de pieza | TH-12CPS |
| Nombre del producto | Hot Melt Glue Detector TH (Discontinued) |
| Tiempo de calentamiento | 40 sec. approx. |
| Rango de detección | 10 to 300 mm 0.394 to 11.811 in(Note) Teaching is possible for this detection range. However, the detection range varies with the size of the sensing object and its temperature, ambient temperature, etc. |
| Número de producto | TH-12CPS |
| Objeto de detección | dia.6 mm dia.0.236 in (equivalent to 3 x 10 mm 0.118 x 0.394 in) or more hot melt glue (emissivity 0.9) at +100 degrees +212 degrees Fahrenheit or more, under ambient temperature of +25 degrees +77 degrees Fahrenheit |
| Tensión de alimentación | 12 to 24 V DC plus or minus10 % Ripple P-P 10 % or less |
| Función de temporizador | Incorporated with approx. 40 ms fixed OFF-delay timer, switchable either effective or ineffective |
| Grado de contaminación | 3 (Industrial environment) |
| Temperatura ambiente | 0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: –10 to +60 degrees +14 to +140 degrees Fahrenheit |
| Consumo actual | 100 mA or less |
| Ajuste de sensibilidad | Teaching method (Push-button operation) |
| Controlador aplicable | TH-C2P |
| Cabezal de sensor aplicable | TH-12 |
| Función de almacenamiento de niveles | Sensitivity levels of eight channels can be stored. |
| Salidas (OUT 1, OUT 2) | PNP open-collector transistor• Maximum source current: 100 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 100 mA source current) |
| Tiempo de respuesta (frecuencia de operación) | Sensing distance 200 mm 7.874 in or less: 1 ms or less (1 to 200 Hz), Sensing distance 300 mm 11.811 in or less: 1.5 ms or less (1 to 100 Hz) |
| Función de selección de canal externo | Incorporated |
| Salidas (OUT 1, OUT 2): Operación de salida | OUT 1: ON when hot melt adhesive is detected (Max. 1 sec. approx.), OUT 2: OFF when the evaluated result is NG (Max. 1 sec. approx.) |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación