| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 0.2 mm24-core cabtyre cable, 2 m6.562 ftlong |
| Producción | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) |
| Peso | Net weight: 55 g approx.Gross weight: 65 g approx. |
| Detalles | Adjustable range reflective |
| Producto | Compact Photoelectric Sensor |
| Material | Enclosure: PBT (Polybutylene terephthalate)Front cover: PolycarbonateIndicator cover: Polycarbonate |
| Histéresis | 5 % or less of operation distance(with white non-glossy paper) |
| Protección | IP67 (IEC) |
| Número de pieza | CX-442 |
| Nombre del producto | Compact Photoelectric Sensor CX-400 Ver.2 |
| Modo de detección | BGS / FGS functions switchable with wiring of sensing mode selection input |
| Repetibilidad | Along sensing axis: 1 mm0.039 inor less, Perpendicular to sensing axis: 0.2 mm0.008 inor less (with white non-glossy paper) |
| Tiempo de respuesta | 1 ms or less |
| Diámetro del punto | Ø15 mmØ0.591 inapprox.(at 300 mm11.811 indistance) |
| Número de producto | CX-442 |
| Tensión de alimentación | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Extensión de cable | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Rango ajustable | 40 to 300 mm1.575 to11.811 in(Note) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can detect an object 2 mm0.079 in[CX-444(-P): 15 mm0.591 in, CX-442(-P): 20 mm0.787 in], or more, away. |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistencia a los golpes | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Ajustador de distancia | 5-turn mechanical adjuster |
| Iluminancia ambiental | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | - 25 to +55℃-13 to +131℃ ℉(No dew condensation or icing allowed ), Storage: -30 to +70℃-22 to +158℃ ℉ |
| Consumo actual | 20 mA or less |
| Indicador de funcionamiento | Orange LED (lights up when the output is ON) |
| Indicador de estabilidad | Green LED(lights up under stable operating condition) |
| Resistencia a la vibración | 10 to 500 Hz frequency, 3 mm0.118 inamplitude in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Salida:Operación de salida | Switchable either Detection-ON or Detection-OFF |
| Soportabilidad de tensión | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Elemento emisor (modulado) | Red LED |
| Cumplimiento de la directiva de marcado CE | EMC Directive, RoHS Directive |
| Salida: Protección contra cortocircuitos | Incorporated |
| Función de prevención automática de interferencias | Incorporated(Note) Note that detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. |
| Rango de detección (con papel blanco no brillante) | 20 to 300 mm0.787 to11.811 in |
| Elemento emisor (modulado):Longitud de onda de emisión máxima | 650 nm0.026 mil |