| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 0.2 mm23-core heat resistant cabtyre cable 2 m3.562 ftlong |
| Observación | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃+73.4 ℉.The sensor head can be used independently. |
| Peso | Net weight : 100 g approx., Gross weight : 150 g approx. |
| Detalles | Sensor head |
| Producto | Head-separated Dual display Digital Pressure Sensor [For gas & liquid] |
| Material | Diaphragm : Stainless steel (SUS603), Pressure port : Stainless steel (SUS304), Throttle : Stainless steel (SUSXM7) |
| Protección | IP67 (IEC) |
| Accesorios | Connector (e-CON) : 1 pc. |
| Número de pieza | DPH-L113 |
| Nombre del producto | Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100 |
| Puerto de presión | R1/4 male thread (throttle embeded) |
| Tiempo de respuesta | 1 ms or less |
| Número de producto | DPH-L113 |
| Tensión de alimentación | 9 to 36 V DC[9 to 32 V DC when using the attached connector (e-CON)] |
| Extensión de cable | Extension up to total 10 m32.808 ftis possible with 0.2 mm2, or more, cable. |
| Humedad ambiental | 35 to 85 % RH, Storage : 35 to 85 % RH |
| Fluido aplicable | Gases and fluids that do not corrode stainless steel SUS630, SUS304, or SUSXM7 |
| Método de puesta a tierra | Capacitor earth (Enclosure-supply terminal) |
| Resistencia a los golpes | 1,000 m/s2acceleration in X, Y and Z directions three times each |
| Tipo de presión | Sealed gauge pressure(Note): The sensor's internal mechanism is sealed based on an air pressure of 1,013 hPa. |
| Método de conexión | Connector |
| Temperatura ambiente | -20 to +70 ℃-4 to +158 ℉(No dew condensation or icing allowed),\n Storage: -30 to +70℃-22 to +158 ℉ |
| Consumo actual | 20 mA or less |
| Rango de presión nominal | 0 to +1 MPa |
| Resistencia a la vibración | 10 to 2,000 Hz frequency, acceleration 200 m/s2, in X direction for four hours, in Y and Z directions for two hours each(Note): The X, Y, and Z directions are defined as follows : |
| Salida de voltaje analógica | Output voltage: 1 to 5 V DC (over rated pressure range)\n Accuracy: ±1.0 % F.S. (at 23 ±2 ℃+73.4 ±35 ℉)\n ±2.0 % F.S. (at -20 to 70 ℃-4 to +158 ℉)\n (including linearity, hysteresis and repeatability) |
| Resistencia de aislamiento | 100 MΩ, or more, with 50 V DC megger between all supply terminals connected together and enclosure |
| Normativa aplicable | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Rango de temperatura media | -20 to +70 ℃-4 to +158 ℉ |
| Soportabilidad de tensión | 150 V AC for one min. between all supply terminals connected together and enclosure |
| Soportabilidad a la presión | 2 MPa |