Horario de atención: Lunes a Viernes 9:00-18:00
UEFS1C - UEFS1C EFS1C EF-S1C PANASONIC Electro static sensor controller for Serie EFS1, 1 x NPN, Analog 1-5V, 24V DC
En stock Producto destacado

UEFS1C

UEFS1C EFS1C EF-S1C PANASONIC Electro static sensor controller for Serie EFS1, 1 x NPN, Analog 1-5V, 24V DC

$0.00USD
3077 en stock
Especificaciones clave
Artículo:Specifications
Cable:0.2 mm26-core cabtyre cable, 2 m 6.562 ft long
Peso:Net weight: 65 g approx., Gross weight: 110 g approx.
Detalles:Controller
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
Cable0.2 mm26-core cabtyre cable, 2 m 6.562 ft long
PesoNet weight: 65 g approx., Gross weight: 110 g approx.
DetallesController
ProductoElectrostatic Sensor
MaterialEnclosure: Heat-resistant ABS, Case cover: Polycarbonate, Mode key: Acrylic, Jog switch: Heat-resistant ABS
Linealidadplus or minus0.5 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be equal to the displayed values plus or minus5 %.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output.
Número de piezaEF-S1C
Nombre del productoElectrostatic Sensor EF-S1
Salida analógicaAnalog voltage• Output voltage: 1 to 5 V• Output impedance: 100 Ohm approx.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output.
Repetibilidadplus or minus0.3 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.
Número de productoEF-S1C
Tensión de alimentación24V DC plus or minus10 %
Extensión de cableExtension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
Humedad ambiental35 to 85 % RH, Storage: 35 to 85 % RH
Temperatura ambiente–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ – 4 to +158 ℉
Consumo actualNormal operation: 50 mA or less, ECO mode: 40 mA or less
Cabezal de sensor aplicableEF-S1HS
Rango de visualización (modo de rango)–1,000 to 1,000 (plus or minus1 kV range mode)–1,999 to 1,999 (plus or minus2kV range mode)(Note) The display range (measurement range) is switched automatically when the measurement distance setting is changed at the controller.
Salida analógica: Tiempo de respuesta20 ms, 30 ms (STD), 110 ms, 210 ms, 410 ms, 810 ms switching method
Características de temperatura0.05 % F.S./℃(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be 0.5 %/℃ of the displayed values.
Entrada de temporización / entrada de ajuste 0NPN non-contact input• Signal conditionHigh: +V or open,Low: 0 to +2 V (source current 0.5 mA or less)• Input impedance: 10 kOhm approx.
Salidas de juicio (SALIDA 1, SALIDA 2)NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: 30 V DC or less (between judgment output and 0 V)• Residual voltage: 1.5 V or less (at 100 mA sink current)
Directivas de conformidad con el marcado CEEMC Directive, RoHS Directive
Salidas de juicio (SALIDA 1, SALIDA 2): Tiempo de respuesta10 ms, 20 ms (STD), 100 ms, 200 ms, 400 ms, 800 ms switching method
Salidas de juicio (SALIDA 1, SALIDA 2): Operación de salidaOUT1: +potential measurement output or window comparator outputOUT2: –potential measurement output or error output
Salidas de juicio (OUT 1, OUT 2): Protección contra cortocircuitoIncorporated

Descripción del producto

Electrostatic sensor controller, dual display, analog output
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top