| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 0.2 mm26-core cabtyre cable, 2 m 6.562 ft long |
| Peso | Net weight: 65 g approx., Gross weight: 110 g approx. |
| Detalles | Controller |
| Producto | Electrostatic Sensor |
| Material | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Mode key: Acrylic, Jog switch: Heat-resistant ABS |
| Linealidad | plus or minus0.5 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be equal to the displayed values plus or minus5 %.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| Número de pieza | EF-S1C |
| Nombre del producto | Electrostatic Sensor EF-S1 |
| Salida analógica | Analog voltage• Output voltage: 1 to 5 V• Output impedance: 100 Ohm approx.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| Repetibilidad | plus or minus0.3 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode. |
| Número de producto | EF-S1C |
| Tensión de alimentación | 24V DC plus or minus10 % |
| Extensión de cable | Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Temperatura ambiente | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ – 4 to +158 ℉ |
| Consumo actual | Normal operation: 50 mA or less, ECO mode: 40 mA or less |
| Cabezal de sensor aplicable | EF-S1HS |
| Rango de visualización (modo de rango) | –1,000 to 1,000 (plus or minus1 kV range mode)–1,999 to 1,999 (plus or minus2kV range mode)(Note) The display range (measurement range) is switched automatically when the measurement distance setting is changed at the controller. |
| Salida analógica: Tiempo de respuesta | 20 ms, 30 ms (STD), 110 ms, 210 ms, 410 ms, 810 ms switching method |
| Características de temperatura | 0.05 % F.S./℃(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be 0.5 %/℃ of the displayed values. |
| Entrada de temporización / entrada de ajuste 0 | NPN non-contact input• Signal conditionHigh: +V or open,Low: 0 to +2 V (source current 0.5 mA or less)• Input impedance: 10 kOhm approx. |
| Salidas de juicio (SALIDA 1, SALIDA 2) | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: 30 V DC or less (between judgment output and 0 V)• Residual voltage: 1.5 V or less (at 100 mA sink current) |
| Directivas de conformidad con el marcado CE | EMC Directive, RoHS Directive |
| Salidas de juicio (SALIDA 1, SALIDA 2): Tiempo de respuesta | 10 ms, 20 ms (STD), 100 ms, 200 ms, 400 ms, 800 ms switching method |
| Salidas de juicio (SALIDA 1, SALIDA 2): Operación de salida | OUT1: +potential measurement output or window comparator outputOUT2: –potential measurement output or error output |
| Salidas de juicio (OUT 1, OUT 2): Protección contra cortocircuito | Incorporated |