| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Peso | Net weight : 370 g approx. |
| Detalles | Head |
| Producto | Pulse AC Method Area Ionizer |
| Material | Main unit enclosure: Stainless steal (SUS)Head mounting bracket: Stainless steal (SUS)Discharge needle: PFA, Tungsten |
| Accesorios | Head mounting bracket (installed at the time of factory shipment) |
| equilibrio iónico | ±30 V or less(Note 1:Typical value in condition of discharge distance 100 mm3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)(Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.) |
| Número de pieza | ER-X001 |
| Nombre del producto | Pulse AC Method Area Ionizer ER-X |
| Número de producto | ER-X001 |
| Humedad ambiental | 35 to 65 % RH, Storage: 35 to 85 % RH |
| Fluido aplicable | Air (dried clean air)(Note:The dried clean air is the air dried (dew point: equivalent of -20 ℃-4 ℉) and filtered (mesh-size: equivalent of 0.01 μm) .) |
| Método de descarga | Pulse AC method(Note:The discharge frequencies of 50 Hz, 20 Hz are accepted.) |
| Generación de ozono | 0.01 ppm or less(Note:Typical value in condition of discharge distance 50 mm1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
| Resistencia a los golpes | 100 m/s2acceleration (10 G approx.), in X, Y and Z directions three times each |
| Puesta a tierra del envolvente | Floating |
| Altitud de operación | 2,000 m6561.68 ftor less(Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.) |
| Temperatura ambiente | 0 to +40 ℃+32 to +104 ℉(No dew condensation), Storage: -10 to +65℃+14 to +149℉ |
| Tiempo de eliminación de carga | 0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2)(Note 1: Typical value in condition of discharge distance 50 mm1.969 in, center of the product, discharge wavelength 50 Hz and air supply 60 ℓ / min. (0.3 MPa)) .(Note 2: Typical value in condition of discharge distance 50 mm1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
| Frecuencia de descarga | 50 Hz / 20 Hz |
| Presión máxima de aire | 0.5 MPa |
| Resistencia a la vibración | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Normativa aplicable | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) |
| Voltaje de salida de descarga | ±7,000 V approx. |
| Longitud del cable de alta tensión | 1.2 m3.937 ft |
| Ancho efectivo de eliminación de carga | 50 mm1.969 inapprox. |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación