| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Producción | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Detalles | Thru-beam type |
| Producto | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accesorio | MS-EXL2-2 (Mounting plate): 2 pcs. |
| Protección | IP67 (IEC) |
| Número de pieza | EX-L211-P-J |
| Nombre del producto | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Repetibilidad | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| Tiempo de respuesta | 0.5 ms or less |
| Rango de detección | 1 m3.281 ft |
| Número de producto | EX-L211-P-J |
| Objeto de detección | Opaque object of ø2 mmø0.079 inor more |
| Tensión de alimentación | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Indicador de encendido | Green LED (lights up when the power is ON) (incorporated on the emitter) |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emisor | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 1 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Resistencia a los golpes | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Iluminancia ambiental | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consumo actual | Emitter: 10 mA or lessReceiver: 10 mA or less |
| Indicador de funcionamiento | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) |
| Indicador de estabilidad | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) |
| Ajustador de sensibilidad | Continuously variable adjuster (incorporated on the receiver) |
| Resistencia a la vibración | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Cumplimiento normativo | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Salida:Operación de salida | Light-ON / Dark-ON selectable by the output operation switching input |
| Soportabilidad de tensión | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Tamaño del punto de emisión (típico) | Approx. 6 × 4 mm0.236 × 0.157 in(vertical × horizontal)(at a sensing distance of 1 m) |
| Salida: Protección contra cortocircuitos | Incorporated (short-circuit protection / inverse polarity protection) |
| Objeto de detección mínimo (típico) | Opaque object of ø0.3 mmø0.012 in(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
| Repetibilidad (típica) (perpendicular al eje de detección) | 0.01 mm0.0004 inor less(all area)(Note)Typical values when the sensitivity adjuster is optimally adjusted. |