Horario de atención: Lunes a Viernes 9:00-18:00
UEXL212P - UEXL212P EX-L212-P PANASONIC Laser Trough beam, 3m, spot 8x5,5mm, PNP, cable 2m
En stock Producto destacado

UEXL212P

UEXL212P EX-L212-P PANASONIC Laser Trough beam, 3m, spot 8x5,5mm, PNP, cable 2m

$0.00USD
3007 en stock
Especificaciones clave
Artículo:Specifications
Cable:0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong
Producción:PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
Peso:Net weight: Emitter: 40 g approx., Receiver: 40 g approx.,Gross weight: 90 g approx.
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
Cable0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong
ProducciónPNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
PesoNet weight: Emitter: 40 g approx., Receiver: 40 g approx.,Gross weight: 90 g approx.
DetallesThru-beam type
ProductoAmplifier Built-in Ultra-compact Laser Sensor
MaterialEnclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
AccesorioMS-EXL2-2 (Mounting plate): 2 pcs.
ProtecciónIP67 (IEC)
Número de piezaEX-L212-P
Nombre del productoAmplifier Built-in Ultra-compact Laser Sensor EX-L200
RepetibilidadPerpendicular to sensing axis: 0.05 mm0.0020 inor less
Tiempo de respuesta0.5 ms or less
Rango de detección3 m9.843 ft
Número de productoEX-L212-P
Objeto de detecciónOpaque object of ø3 mmø0.118 inor more
Tensión de alimentación12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Indicador de encendido-
Humedad ambiental35 to 85 % RH, Storage: 35 to 85 % RH
Elemento emisorRed semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 1 mW, Peak emission wavelength: 655 nm0.026 mil)
Resistencia a los golpes500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Iluminancia ambientalIncandescent light: 3,000 lx or less at the light-receiving face
Temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉
Consumo actualEmitter: 10 mA or lessReceiver: 10 mA or less
Indicador de funcionamientoOrange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Indicador de estabilidadGreen LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
Ajustador de sensibilidad-
Resistencia a la vibración10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each
Resistencia de aislamiento20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Cumplimiento normativoCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Salida:Operación de salidaLight-ON / Dark-ON selectable by the output operation switching input
Soportabilidad de tensión1,000 V AC for one min. between all supply terminals connected together and enclosure
Tamaño del punto de emisión (típico)Approx. 8 × 5.5 mm0.315 × 0.217 in(vertical × horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 3 m9.843 ft, the emission spot size is H 17 × W 11 mmH 0.669 × W 0.433 in(visual reference value).
Salida: Protección contra cortocircuitosIncorporated (short-circuit protection / inverse polarity protection)
Objeto de detección mínimo (típico)-
Repetibilidad (típica) (perpendicular al eje de detección)-

Descripción del producto

Digital laser barrier, detection range 3m, spot 8x5.5mm, PNP, cable 2m, IP67, without sensitivity adjustment
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top