| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Producción | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Detalles | Spot reflective type |
| Producto | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accesorio | MS-EXL2-3 (Mounting plate): 1 pc. |
| Histéresis | 20 % or less of operation distance |
| Protección | IP67 (IEC) |
| Número de pieza | EX-L221-P-C5 |
| Nombre del producto | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Repetibilidad | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| Tiempo de respuesta | 0.5 ms or less |
| Rango de detección | 45 to 300 mm1.772 to 11.811 in(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Número de producto | EX-L221-P-C5 |
| Objeto de detección | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Tensión de alimentación | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Extensión de cable | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable. |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Elemento emisor | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 2 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Resistencia a los golpes | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Iluminancia ambiental | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consumo actual | 15 mA or less |
| Ajustador de sensibilidad | Continuously variable adjuster |
| Resistencia a la vibración | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Cumplimiento normativo | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Salida:Operación de salida | Light-ON / Dark-ON selectable by the output operation switching input |
| Soportabilidad de tensión | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Tamaño del punto de emisión (típico) | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Salida: Protección contra cortocircuitos | Incorporated (short-circuit protection / inverse polarity protection) |
| Objeto de detección mínimo (típico) | Gold wire of ø0.01 mmø0.0004 in(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
| Función de prevención automática de interferencias | Incorporated(Two sensors can be mounted close together.) |
| Repetibilidad (típica) (perpendicular al eje de detección) | 0.02 mm0.0008 inor less(at 100 to 200 mm sensing distance)(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
Especificaciones técnicas y datos de rendimiento