| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 0.15 mm24-core cabtyre cable, 2 m6.562 ftlong |
| Producción | PNP open-collector transistor- Maximum source current: 50 mA |
| Peso | Net weight: 45 g approxGross weight: 60 g approx |
| Detalles | Convergent reflective type |
| Producto | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accesorio | MS-EXL2-3 (Mounting plate): 1 pc. |
| Histéresis | 20 % or less of operation distance |
| Protección | IP67(IEC) |
| Número de pieza | EX-L261-P |
| Nombre del producto | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Repetibilidad | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| Tiempo de respuesta | 0.5 ms or less |
| Rango de detección | 20 to 50 mm0.787 to 1.969 in(Convergent point: 22 mm0.866 in)(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Número de producto | EX-L261-P |
| Objeto de detección | Opaque, translucent or transparent object(Note)Make sure to confirm detection with an actual sensor before use. |
| Tensión de alimentación | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Extensión de cable | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable |
| Humedad ambiental | 35 to 85%RH , Storage: 35 to 85%RH |
| Elemento emisor | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS)(Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).)(Maximum output: 1 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Consumo actual | 15 mA or less |
| Ajustador de sensibilidad | Continuously variable adjuster |
| Cumplimiento normativo | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Salida:Operación de salida | Light-ON / Dark-ON selectable by the output operation switching input |
| Tamaño del punto de emisión (típico) | ø1mm0.039 inor less (at a sensing distance of 50 mm) |
| Salida: Protección contra cortocircuitos | Incorporated (short-circuit protection / inverse polarity protection) |
| Objeto de detección mínimo (típico) | Gold wire of ø0.01 mmø0.0004 in(Note) Typical values when the sensitivity adjuster is optimally adjusted. |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación