| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 5-core composite cable, 2 m6.5617 ftlong |
| Peso | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) |
| Detalles | Measurement center 100mm 3.937 in type |
| Producto | CMOS type Micro Laser Distance Sensor |
| Material | Enclosure: Aluminum die-castFront cover: Acrylic |
| Linealidad | ±0.1%F.S. |
| Protección | IP67 (IEC) |
| Número de pieza | HG-C1100-P |
| Fuente de luz | Red semiconductor laser Class 2 (IEC / EN/ JIS / GB / KS / FDA) / Class II (FDA)(Note)Max. output: 1mWemission peak wavelength: 655nm 0.026 mil(Note) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Nombre del producto | CMOS type Micro Laser Distance Sensor HG-C |
| Diámetro de la viga | ø120 μm4.7241 milapprox.(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2(13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. |
| Repetibilidad | 70 μm2.756 mil |
| Tiempo de respuesta | Switchable between 1.5 ms / 5 ms / 10 ms |
| Salida de control | PNP open-collector transistor- Maximum source current: 50mA- Applied voltage: 30V DC or less (Between control output to +V)- Residual voltage: 1.5V or less (At 50mA source current)- Leakage current: 0.1 mA or less |
| Entrada externa | PNP non-contact input- Input conditionsInvalid: 0 to +0.6V DC or OpenValid: +4 to +V DC- Input impedance: 10kΩ approx. |
| Número de producto | HG-C1100-P |
| Tensión de alimentación | 12 to 24V DCplus or minus 10% Ripple P-P 10% |
| Extensión de cable | Extension up to total 10 m393.701 ftis possible with 0.3 mm2, or more, cable. |
| Rango de medición | ±35mm1.328 in |
| Humedad ambiental | 35 to 85% RH, Storage: 35 to 85% RH |
| Grado de contaminación | 2 |
| Resistencia a los golpes | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Altitud de operación | 2,000 m6561.680 ftor less |
| Iluminancia ambiental | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Temperatura ambiente | -10 to +45 ℃-14 to 113 ℉(No dew condensation or icing allowed), Storage: -20 to +60 ℃-4 to 140 ℉ |
| Consumo actual | 40 mA or less (at 24V DC supply voltage)65 mA or less (at 12V DC supply voltage)Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) |
| Resistencia a la vibración | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Distancia del centro de medición | 100mm3.937 in |
| Características de temperatura | 0.03% F.S. /℃ |
| Salida de control: Operación de salida | Either Light-ON or Dark-ON |
| Salida analógica: Salida de corriente analógica | • Output range: 4 to 20mA (at alarm: 0mA)• Output impedance: 300Ω or lessNote : Analog current output has been added from shipment in August 2016. |
| Salida analógica: Salida de tensión analógica | • Output range: 0 to 5 V (at alarm: +5.2 V)• Output impedance: 100Ω |
| Salida de control: Protección contra cortocircuitos | Incorporated (Auto reset type) |
| Normativas y certificaciones aplicables | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification(Note) : The UL/c-UL certified products have been shipped since April, 2017. |
Especificaciones técnicas y datos de rendimiento