| Parámetro | Valor |
|---|---|
| When communication unitis connected | |
| Artículo | Specifications |
| Cable | 0.15 mm27-core composite cable, 2 m6.562 ftlong |
| Detalles | Slave unit / High performance type |
| Producto | Controller |
| Material | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| Peso neto | 140 g approx. |
| Número de pieza | HG-TC111 |
| 1 a 7 unidades | 1 to 6 units |
| Nombre del producto | Thru-beam Type Digital Displacement Sensor HG-T |
| 8 a 15 unidades | 7 to 14 units |
| Rango de visualización | -199.999 to 199.999 mm-7.874 to 7.874 in |
| Frecuencia de muestreo | 1 ms (standard sampling) / 0.5 ms (high-speed sampling) |
| Número de producto | HG-TC111 |
| Tensión de alimentación | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Grado de contaminación | 2 |
| Resolución de pantalla | 1 μm0.039 mil |
| Altitud de operación | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Consumo actual | 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output. |
| Cumplimiento normativo | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Cabezal de sensor aplicable | HG-T1010、HG-T1110 |
| Conmutación de entrada externa | Input 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop". |
| Conmutación de salida externa | Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2. |
| Recuento promedio (tiempo de respuesta) | 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Número de unidades esclavas conectadas | Maximum sink current and sourcecurrent of control output |
| Resistencia ambiental: Protección | IP40(IEC) |
| Salida analógica: Salida de corriente analógica | •Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| Salida analógica: Salida de tensión analógica | •Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| Entrada externa (Entrada 1, Entrada 2, Entrada 3) | Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx. |
| Número máximo de controladores conectables | Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| Resistencia ambiental: Humedad ambiente | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistencia ambiental: Resistencia a los golpes | 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Salida de control (Salida 1, Salida 2, Salida 3) | NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Resistencia ambiental: Temperatura ambiente | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Resistencia ambiental: Resistencia a la vibración | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each |
| Resistencia ambiental: Resistencia de aislamiento | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Resistencia ambiental: Soportabilidad al voltaje | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
| Entrada externa (Entrada 1, Entrada 2, Entrada 3): Tiempo de entrada | • Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Salida de control (Salida 1, Salida 2, Salida 3): Salida de alarma | Open when alarm occurs |
| Salida de control (Salida 1, Salida 2, Salida 3): Salida de juicio | N.O. / N.C. switching type |
| Salida de control (Salida 1, Salida 2, Salida 3): Protección contra cortocircuitos | Incorporated (automatic reset type) |
Especificaciones técnicas y datos de rendimiento