Especificaciones clave
:When communication unitis connected
Artículo:Specifications
Cable:0.15 mm27-core composite cable, 2 m6.562 ftlong
Detalles:Slave unit / High performance type
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
When communication unitis connected
ArtículoSpecifications
Cable0.15 mm27-core composite cable, 2 m6.562 ftlong
DetallesSlave unit / High performance type
ProductoController
MaterialCase: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Peso neto140 g approx.
Número de piezaHG-TC111-P
1 a 7 unidades1 to 6 units
Nombre del productoThru-beam Type Digital Displacement Sensor HG-T
8 a 15 unidades7 to 14 units
Rango de visualización-199.999 to 199.999 mm-7.874 to 7.874 in
Frecuencia de muestreo1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Número de productoHG-TC111-P
Tensión de alimentación24 V DC ±10 %, including ripple 0.5 V (P-P)
Grado de contaminación2
Resolución de pantalla1 μm0.039 mil
Altitud de operación2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Consumo actual100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output.
Cumplimiento normativoCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Cabezal de sensor aplicableHG-T1010、HG-T1110
Conmutación de entrada externaInput 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
Conmutación de salida externaOutput 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
Recuento promedio (tiempo de respuesta)1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Número de unidades esclavas conectadasMaximum sink current and sourcecurrent of control output
Resistencia ambiental: ProtecciónIP40(IEC)
Salida analógica: Salida de corriente analógica•Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Salida analógica: Salida de tensión analógica•Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Entrada externa (Entrada 1, Entrada 2, Entrada 3)Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx.
Número máximo de controladores conectablesUp to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Resistencia ambiental: Humedad ambiente35 to 85 % RH, Storage: 35 to 85 % RH
Resistencia ambiental: Resistencia a los golpes98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Salida de control (Salida 1, Salida 2, Salida 3)NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Resistencia ambiental: Temperatura ambiente-10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Resistencia ambiental: Resistencia a la vibración10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each
Resistencia ambiental: Resistencia de aislamiento20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Resistencia ambiental: Soportabilidad al voltaje1,000 V AC for one minute between all supply terminals connected together and enclosure
Entrada externa (Entrada 1, Entrada 2, Entrada 3): Tiempo de entrada• Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Salida de control (Salida 1, Salida 2, Salida 3): Salida de alarmaOpen when alarm occurs
Salida de control (Salida 1, Salida 2, Salida 3): Salida de juicioN.O. / N.C. switching type
Salida de control (Salida 1, Salida 2, Salida 3): Protección contra cortocircuitosIncorporated (automatic reset type)

Descripción del producto

HG-T Laser Displacement Sensor. High Functionality Slave Controller, PNP Output