| Parámetro | Valor |
|---|---|
| When communication unitis connected | |
| Artículo | Specifications |
| Cable | 0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong |
| Detalles | Slave unit / Wire-saving type |
| Producto | Controller |
| Material | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| Peso neto | 60 g approx. |
| Número de pieza | HG-TC113 |
| 1 a 7 unidades | 1 to 6 units |
| Nombre del producto | Thru-beam Type Digital Displacement Sensor HG-T |
| 8 a 15 unidades | 7 to 14 units |
| Rango de visualización | -199.999 to 199.999 mm-7.874 to 7.874 in |
| Frecuencia de muestreo | 1 ms (standard sampling) / 0.5 ms (high-speed sampling) |
| Número de producto | HG-TC113 |
| Tensión de alimentación | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Grado de contaminación | 2 |
| Resolución de pantalla | 1 μm0.039 mil |
| Altitud de operación | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Consumo actual | 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output. |
| Cumplimiento normativo | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Cabezal de sensor aplicable | HG-T1010、HG-T1110 |
| Recuento promedio (tiempo de respuesta) | 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Número de unidades esclavas conectadas | Maximum sink current and sourcecurrent of control output |
| Resistencia ambiental: Protección | IP40(IEC) |
| Número máximo de controladores conectables | Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| Resistencia ambiental: Humedad ambiente | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistencia ambiental: Resistencia a los golpes | 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Resistencia ambiental: Temperatura ambiente | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Resistencia ambiental: Resistencia a la vibración | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each |
| Resistencia ambiental: Resistencia de aislamiento | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Resistencia ambiental: Soportabilidad al voltaje | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación