Horario de atención: Lunes a Viernes 9:00-18:00
UHLAC1 - UHLAC1 HLAC1 HL-AC1 PANASONIC HL-T1 sensor controller, NPN, 12-24VDC
En stock Producto destacado

UHLAC1

UHLAC1 HLAC1 HL-AC1 PANASONIC HL-T1 sensor controller, NPN, 12-24VDC

$0.00USD
3192 en stock
Especificaciones clave
Artículo:Specifications
Tipo:NPN output
Peso:Net weight: 140 g approx.
Detalles:Controller (NPN output)
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
TipoNPN output
PesoNet weight: 140 g approx.
DetallesController (NPN output)
ProductoUltra-compact Laser Collimated Beam Sensor
MaterialEnclosure: Polybutylene terephthalateTransparent cover: Polycarbonate
Cable de E/S0.09 mm210-core composite cable, 2 m6.562 ftlong
Número de piezaHL-AC1
Restablecer entrada0 V connection: EffectiveOpen: Ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
Nombre del productoUltra-compact Laser Collimated Beam Sensor HL-T1
Entrada de tiempo0 V connection: EffectiveOpen: Ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
Salida linealCurrent / voltage output switchable (Note)-During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ohm-During voltage output: plus or minus 4 V/F.S., Output impedance 100 Ohm(In the monitor focus function, it can also be set at plus or minus 5 V, 0 to 5 V, etc.)(Note) Switching between current and voltage is accomplished by a switch on the bottom of the controller.
Funciones principales・Measured value display・Setting value, light amount value resolution display・Standard received light setting・Automatic scaling・Scaling・Display reverse・ECO display・Display digits limitation・Sample hold・Peak hold・Bottom hold・Peak to peak hold・Self peak hold・Self bottom hold・Zero reset・Initial reset・ON-delay timer・OFF-delay timer・One-shot timer・Differentiation・Sensitivity selection・Threshold value direct setting・Positioning teaching・2-point teaching・Automatic teaching・Hysteresis width variability・Monitor focus・Non-measuring time setting・(A – B) calculation(Note:The calculation unit is necessary.)・(A + B) calculation(Note:The calculation unit is necessary.)・Mutual interference prevention (Note:The calculation unit is necessary.)・Laser deterioration detection・Key lock・Zero reset memory
Número de productoHL-AC1
Tensión de alimentación12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Entrada de láser apagado0 V connection: Laser emission haltOpen: Laser emission-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
Ciclo de medición150 micro s
Grado de contaminación3 (industrial environment)
Entrada de reinicio a cero0 V connection: Zero reset operatesOpen: Zero reset ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
Consumo actual190 mA or less (when connected to the sensor head)
Extensión de cable de E/SExtension up to total 10 m32.808 ftis possible, with 0.09 mm2or more, cable.(Note) If the extension cable is longer than 10 m32.808 ft, then it will not qualify for CE marking.
Pantalla subdigital5 digit yellow LED display[RUN mode: Either the resolution or laser beam reception amount will be displayed. THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed.]
Pantalla digital principal5 digit red LED display[RUN mode: Either the measured value (mm) or the hold value will be displayed. Reverse mode: The display orientation will be reversed.]
Resistencia de aislamiento20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Cabezal de sensor aplicableHL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F
Soportabilidad de tensión1,000 V AC for one min. between all supply terminals connected together and enclosure
Indicadores: Habilitar (ENABLE)Green LED (lights up during normal operation)
Indicadores: Resultados del juicioHIGH: Orange LED (lights up when measured value > HIGH threshold value)PASS: Green LED (lights up when HIGH threshold value >= measured value >= LOW threshold value)LOW: Yellow LED (lights up when LOW threshold value > measured value)
Indicadores: Puesta a cero (ZERO)Green LED (lights up when the zero reset function is enabled)
Frecuencia de muestreo promedio configurable1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096(Note) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) x (Set average sampling rate + 1).
Cumplimiento de la directiva de marcado CEEMC Directive, RoHS Directive
Resultados de juicio (ALTO, APROBADO, BAJO)NPN open-collector transistor-Maximum sink current: 50 mA-Applied voltage: 30 V DC or less (between judgment output and 0 V)-Residual voltage: 1.2 V or less (at 50 mA sink current)
Indicadores: emisión láser (LD activado)Green LED (lights up during laser emission)
Resistencia ambiental: Humedad ambiente35 to 85 % RH, Storage: 35 to 85 % RH
Resistencia ambiental: Resistencia a los golpes300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each
Salida lineal: Características de temperaturaplus or minus 0.2 % F.S./℃(Note) These are the temperature characteristics of the linear output when the sensor head is connected.
Resistencia ambiental: Temperatura ambiente0 to +50 ℃+32 to +122 ℉(No dew condensation allowed), Storage: -25 to +65 ℃-13 to +149 ℉
Resistencia ambiental: Resistencia a la vibración10 to 150 Hz frequency, 0.7 mm0.028 indouble amplitude in X, Y and Z directions for 80 min.
Salidas de juicio (ALTO, PASA, BAJO): Operación de salidaHIGH: ON when measured value > HIGH threshold valuePASS: ON when HIGH threshold value >= measured value >= LOW threshold valueLOW: ON when LOW threshold value > measured value
Salidas de juicio (ALTO, APROBADO, BAJO): Número de salidasHIGH / PASS / LOW 3 values output
Resultados de la evaluación (ALTO, APROBADO, BAJO): Categoría de utilizaciónDC-12 or DC-13
Salidas de juicio (ALTO, PASA, BAJO): Protección contra cortocircuitoIncorporated

Descripción del producto

HLT1 Series Controller, 12-24 VDC Power, NPN Digital Output, Selectable Analog Output between 4-20mA and ±4V
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top