| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 0.1 mm2, single core two parallel shielded cables, 2 m6.562 ftlong (Connector for amplifier attached)(Note) Cable cannot be extended. |
| Peso | Net weight: 30 g approxGross weight: 45 g approx |
| Detalles | Sensor head (Coaxial retroreflective type) |
| Producto | Digital Laser Sensor |
| Material | Enclosure: PBT (Mounting part: PEI)Lens cover: Acrylic |
| Accesorio | RF-330(Reflector): 1 pc.Warning label: 1 set(Labels are written in Japanese, English and Chinese for compliance with various standards.) |
| Protección | IP40 (IEC) |
| Número de pieza | LS-H91 |
| Nombre del producto | Digital Laser Sensor LS-400 |
| Número de producto | LS-H91 |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistencia a los golpes | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Iluminancia ambiental | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage:-20 to +70 ℉ |
| Indicador de funcionamiento | Orange LED (lights up when the amplifier output is ON) |
| Ajustador de forma de punto | - |
| Resistencia a la vibración | 10 to 500 Hz frequency, 1.5 mm0.059 in(10 G max.) double amplitude in X, Y and Z directions for two hours each |
| Amplificadores aplicables | LS-401(P), LS-401(P)-C2, LS-403 |
| Resistencia de aislamiento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Rango de detección: modo STD | 0.1 to 5 m0.328 to16.404 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
| Rango de detección: modo RÁPIDO | 0.1 to 3 m0.328 to 9.843 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
| Rango de detección: modo H-SP | 0.1 to 3 m0.328 to 9.843 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
| Rango de detección: modo U-LG | 0.1 to 7 m0.328 to 22.966 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. |
| Indicador de emisión láser | Green LED (lights up during laser emission) |
| Soportabilidad de tensión | 1,000 V AC for one min.between all supply terminals connected together and enclosure |
| Cumplimiento de la directiva de marcado CE | EMC Directive, RoHS Directive |
| Elemento emisor: Tipo conforme a las normas IEC/JIS/GB | Red semiconductor laser,Class 2 (IEC / JIS / GB)(Max. output: 3 mW Peak emission wavelength: 655 nm0.026 mil) |
| Elemento emisor: Tipo conforme a las normas FDA / IEC / JIS | Red semiconductor laser,Class 2 (FDA / IEC / JIS)(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. |
Especificaciones técnicas y datos de rendimiento