Artículo:Specifications
Cable:0.1 mm2, single core two parallel shielded cables, 2 m6.562 ftlong (Connector for amplifier attached)(Note) Cable cannot be extended.
Peso:Net weight: 30 g approxGross weight: 45 g approx
Detalles:Sensor head (Coaxial retroreflective type)
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
Cable0.1 mm2, single core two parallel shielded cables, 2 m6.562 ftlong (Connector for amplifier attached)(Note) Cable cannot be extended.
PesoNet weight: 30 g approxGross weight: 45 g approx
DetallesSensor head (Coaxial retroreflective type)
ProductoDigital Laser Sensor
MaterialEnclosure: PBT (Mounting part: PEI)Lens cover: Acrylic
AccesorioRF-330(Reflector): 1 pc.Warning label: 1 set(Labels are written in Japanese, English and Chinese for compliance with various standards.)
ProtecciónIP40 (IEC)
Número de piezaLS-H91
Nombre del productoDigital Laser Sensor LS-400
Número de productoLS-H91
Humedad ambiental35 to 85 % RH, Storage: 35 to 85 % RH
Resistencia a los golpes100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
Iluminancia ambientalIncandescent light: 3,000 lx or less at the light-receiving face
Temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage:-20 to +70 ℉
Indicador de funcionamientoOrange LED (lights up when the amplifier output is ON)
Ajustador de forma de punto-
Resistencia a la vibración10 to 500 Hz frequency, 1.5 mm0.059 in(10 G max.) double amplitude in X, Y and Z directions for two hours each
Amplificadores aplicablesLS-401(P), LS-401(P)-C2, LS-403
Resistencia de aislamiento20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Rango de detección: modo STD0.1 to 5 m0.328 to16.404 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Rango de detección: modo RÁPIDO0.1 to 3 m0.328 to 9.843 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Rango de detección: modo H-SP0.1 to 3 m0.328 to 9.843 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Rango de detección: modo U-LG0.1 to 7 m0.328 to 22.966 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Indicador de emisión láserGreen LED (lights up during laser emission)
Soportabilidad de tensión1,000 V AC for one min.between all supply terminals connected together and enclosure
Cumplimiento de la directiva de marcado CEEMC Directive, RoHS Directive
Elemento emisor: Tipo conforme a las normas IEC/JIS/GBRed semiconductor laser,Class 2 (IEC / JIS / GB)(Max. output: 3 mW Peak emission wavelength: 655 nm0.026 mil)
Elemento emisor: Tipo conforme a las normas FDA / IEC / JISRed semiconductor laser,Class 2 (FDA / IEC / JIS)(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.

Descripción del producto

LS Series Digital Laser Sensor Head, Class 2, Coaxial Reflection on Mirror (7m)
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top