| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 0.2 mm23-core cabtyre cable, 1 m3.281 ftlong(Note) Cable cannot be extended. |
| Producción | NPN open-collector transistorMaximum sink current: 100 mAApplied voltage: 30 V DC or less (between output and 0 V)Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Peso | Net weight: 25 g approx.Gross weight: 330 g approx.(10 piece package) |
| Detalles | Cable type L type(Top sensing) |
| Producto | Convergent Reflective Micro Photoelectric Sensor PM2 |
| Material | Enclosure: Polycarbonate, Fixed cable part: PBT |
| Histéresis | 20 % or less of operation distance with white non-glossy paper(15 × 15 mm0.591 × 0.591 in) |
| Número de pieza | PM2-LL10-C1 |
| Longitud del cable | - |
| Nombre del producto | Convergent Reflective Micro Photoelectric Sensor PM2 |
| Tiempo de respuesta | 0.8 ms or less |
| Rango de detección | 2.5 to 8 mm0.098 to 0.315 in(Conv. point: 5 mm0.197 in) with white non-glossy paper (15 × 15 mm0.591 in × 0.591 in)(Note)The sensing range may extend up to 12.5 mm0.492 inwith white non-glossy paper due to product variation. |
| Número de producto | PM2-LL10-C1 |
| Tensión de alimentación | 5 to 24 V DC plus or minus 10 % Ripple P-P 5 % or less |
| Humedad ambiental | 45 to 85 % RH, Storage: 45 to 85 % RH |
| Elemento emisor | Infrared LED (Peak emission wavelength: 880 nm0.035 mil, modulated) |
| Grado de contaminación | 3 (Industrial environment) |
| Resistencia a los golpes | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Iluminancia ambiental | Incandescent light: 3,500 lx or less at the light-receiving face |
| Temperatura ambiente | –10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: –25 to +80 ℃–13 to +176℉ |
| Consumo actual | Average: 25 mA or less, Peak: 80 mA or less |
| Indicador de funcionamiento | Red LED (lights up when the output is ON) |
| Resistencia a la vibración | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Directivas de marcado CE | EMC Directive, RoHS Directive |
| Objeto de detección mínimo | ø0.05 mmø0.002 incopper wire (Setting distance: 5 mm0.197 in) |
| Salida:Categoría de utilización | DC-12 or DC-13 |
| Salida: Protección contra sobrecorriente | Incorporated |
| Repetibilidad (perpendicular al eje de detección) | 0.08 mm0.003 inor less(Note) The repeatability is specified for white non-glossy paper (15 × 15 mm0.591 × 0.591 in) at a setting distance of 5 mm0.197 in. |
Especificaciones técnicas y datos de rendimiento