| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Peso | Net weight: 75 g approx.Gross weight: 120 g approx. |
| Detalles | Communication unit for EtherCAT |
| Producto | Commnunication Unit for Open Network |
| Material | Enclosure: Polycarbonate |
| Tasa de baudios | 100 Mbps |
| Número de pieza | SC-GU3-03 |
| Nombre del producto | Communication Unit for Open Network SC-GU3 |
| Número de producto | SC-GU3-03 |
| Tensión de alimentación | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Temperatura ambiente | –10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),\n(If 4 to 7 units are connected in cascade: –10 to +50 ℃+14 to +122 ℉,\nif 8 to 16 units are connected in cascade: –10 to +45 ℃+14 to +113 ℉)\nStorage: –20 to +70 ℃–4 to +158 ℉ |
| Cable de comunicación | Category 5e |
| Puertos de comunicación | RJ45 × 2 |
| Norma de cumplimiento | IEEE802.3u |
| Consumo actual | 80 mA or less (at 24 V) (without connected sensor amplifiers) |
| Distancia internodal | 100 m328.1ft |
| Normativa aplicable | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Corriente de paso admisible | Wire-saving connector 2 A(Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. |
| Número de unidades conectables | Maximum of 16 units per SC-GU3-01 unit(Max. 12 units when FX-500 / LS-500 series are connected) |
| Estándares de comunicación EtherCAT | Process data communication, Mailbox communication |