Especificaciones clave
Artículo:Specifications
PFHD:3.18 × 10-9
Cable:0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong
MTTFD:100 years or more
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
PFHD3.18 × 10-9
Cable0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong
MTTFD100 years or more
DetallesMin. sensing object ø14 mmø0.551 intype (10 mm0.394 inbeam pitch) [Cable type]
ProductoUltra-slim Safety Light Curtain [Type 4 PLe SIL3]
MaterialEnclosure: Polycarbonate alloySensing surface: Polycarbonate alloy
Paso de viga10 mm0.394 in
AccesoriosMS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR14 (Test rod): 1 No.
Número de piezaSF4C-F31
Nombre del productoUltra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
Función ELCAIncorporated (reducing mutual interference automatically)
Voltaje de potencia24 V DC +10-15 % Ripple P-P 10 % or less
Tiempo de respuestaOFF response: 9 ms or lessON response: 90 ms or less
Número de productoSF4C-F31
Extensión de cableExtension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver).
Función de silenciamientoIncorporated
Rango de operación0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver.
Elemento emisorInfrared LED (Peak emission wavelength: 855 nm0.034 mil)
Grado de contaminación3
Función de anulaciónIncorporated
Altura de protección320 mm12.598 in
Función de enclavamientoIncorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Altitud de operación2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
Funciones opcionalesFixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required.
Iluminancia ambientalIncandescent light: 5,000 lx or less at the light-receiving face
Mínimo objeto detectadoø14 mmø0.551 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
Número de canales de haz31
Función de entrada de seguridadIncorporated (safety contact)
Ángulo de apertura efectivoplus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)]
Normas aplicables: JapónJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3)
Normas aplicables: EuropaEN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Función de entrada de prueba/reinicioIncorporated
Salidas de control (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less
Normas aplicables: América del NorteANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark.
Función de monitorización de dispositivos externosIncorporated
Salida auxiliar (salida sin seguridad)PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable)
Normativas y certificaciones aplicablesCE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification
Resistencia ambiental: Humedad ambiente30 to 85 % RH, Storage: 30 to 85 % RH
Resistencia ambiental: Resistencia a los golpes300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each
Peso neto (Total de emisor y receptor)730 g approx.
Normas aplicables: Norma internacionalIEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3)
Resistencia ambiental: Temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Resistencia ambiental: Grado de protecciónIP67 / IP65 (IEC)
Resistencia ambiental: Resistencia a la vibración10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each
Resistencia ambiental: Resistencia de aislamiento20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Salidas de control (OSSD 1, OSSD 2): Modo de operaciónON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed.
Salidas de control (OSSD1, OSSD2): Circuito de protecciónIncorporated
Resistencia ambiental: Resistencia a la tensión1,000 V AC for one min. between all supply terminals connected together and enclosure
Salida auxiliar (salida sin seguridad): modo de funcionamientoOFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Salida auxiliar (salida sin seguridad): circuito de protecciónIncorporated
Consumo de corriente: Se enciende el indicador multiusos grande.Emitter: 110 mA or lessReceiver: 115 mA or less
Consumo de corriente: Luces indicadoras multiusos grandes apagadasEmitter: 75 mA or lessReceiver: 85 mA or less

Descripción del producto

SF4C safety barrier category 4, Ple, SIL3, 0.1 to 3m, "finger" protection 10 mm between beams, 13mm thick, protected height 320mm, operating range 0.1 to 3m, cable 5m
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top