Horario de atención: Lunes a Viernes 9:00-18:00
USFC21 - USFC21 SF-C21 PANASONIC Safety control unit for safety light curtain and other safety products, 8 inputs 24V..
En stock Producto destacado

USFC21

USFC21 SF-C21 PANASONIC Safety control unit for safety light curtain and other safety products, 8 inputs 24V..

$0.00USD
4642 en stock
Especificaciones clave
Artículo:Specifications
Peso:Net weight: 190 g approx.Gross weight: 320 g approx.
Producto:Safety Control Unit
Material:Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
PesoNet weight: 190 g approx.Gross weight: 320 g approx.
ProductoSafety Control Unit
MaterialMain unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
PFHD/MTTFD9.73 x 10−10/ 100 years or more
Número de piezaSF-C21
Longitud del cable100 m328.084 ftor less
Nombre del productoSafety Control Unit SF-C21
Número de productoSF-C21
Grado de contaminación2
Método de conexiónInput / output and power supply: Detachable spring cage termina l blocksRS-485: Detachable spring-cage terminal blockUSB: Mini-B male
Normas relacionadasIEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5, IEC 60947-5-8, IEC 61496-1, IEC TS 62046, ISO 13851
Función de enclavamientoIncorporated
Altitud de operación2,000 m6561.680 ftor less(Note) Do not use or store this device in a pressurized environment beyond the atmospheric pressure at sea level.
Resistencia a la vibración5 to 8.4 Hz frequency, 3.5 mm0.138 inhalf amplitude, 8.4 to 150 Hz frequency, Max. acceleration 9.8 m/s2(1 G), in X, Y and Z directions for two hours each (IEC / EN 60068-2-6)
Función de configuración lógicaInput mode, control mode, output mode, reset mode, auxiliary ou tput mode
Categoría de sobretensiónII
Salida del indicador de silenciamientoSemiconductor photo MOS relay output x 1- Maximum load current: 60 mA- Supply voltage: Same as the voltage of the power supply for internal- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Función de liberación de bloqueoIncorporated
Función de selección lógicaNo.0: Customization controlNo.1: Overall stop controlNo.2: Parallel muting controlNo.3: Sequential muting controlNo.4: Partial stop control 1No.5: Partial stop control 2No.6: Two-hand controlNo.7: OR controlNo.8: Operation mode selection control
Entrada de seguridad (IN1 a IN8)2 inputs x 4, Rated voltage: Same as the voltage of the power supply for internal
Normas aplicables: EMCIEC 61000-6-2, IEC 61326-3-1, EN 55011
Tiempo de inicio después del encendido2 sec. or less
Normas aplicables: SeguridadIEC 61508-1 to 3, EN 61508-1 to 3 (SIL3), ISO 13849-1:2015 (Category 4, PLe), IEC 61131-2, IEC 61010-2-201, IEC 62061 (SILCL3), UL 61010-1, UL 61010-2-201, UL 1998
Salida de control (OUT1 a OUT4)PNP open-collector transistor with 2 outputs x 2- Maximum source current: 300 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Función de comunicación (MODBUS RTU)Interface: RS-485Protocol: MODBUS RTUMaximum transmission distance: 100 m328.084 ftMaximum number of units that can be connected: 8 units (slaves)
Función de monitorización de dispositivos externosIncorporated
Entrada de seguridad (IN1 a IN8): nivel ONInput voltage: 18 VInput current: 3.5 mA
Salida del indicador de silenciamiento: Modo de salidaON when muting / override
Entrada de seguridad (IN1 a IN8): nivel OFFInput voltage: 5 VInput current: 1.0 mA
Salida del indicador de silenciamiento: Tiempo de respuesta10 ms or less
Normativas y certificaciones aplicablesCE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety)Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification, Korea's Radio Waves Act conformity registration
Resistencia ambiental: Humedad ambiente30 to 85 % RH, Storage: 30 to 85 % RH
Resistencia ambiental: Resistencia a los golpes147 m/s2(15 G) 11 ms in X, Y and Z directions for three times each (IEC / EN 60068-2-27)
Tensión de alimentación: Alimentación para externa24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Tensión de alimentación: Alimentación para interior24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Salida de control (OUT1 a OUT4): Modo de salidaTrue: ONFalse: OFF
Entrada de seguridad (IN1 a IN8): Impedancia de entrada4.7 KΩ approx.
Resistencia ambiental: Temperatura ambiente-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Salida de control (OUT1 a OUT4): Tiempo de respuestaOFF response: 10 ms or lessON response: 100 ms or less
Resistencia ambiental: Grado de protecciónIP20 (IEC)(must be installed in a control panel with protectio n IP54 or higher)
Resistencia ambiental: Resistencia de aislamiento20 MΩ, or more, with 500 V DC megger(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Consumo de corriente: Fuente de alimentación para externa100 mA or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Consumo de corriente: Fuente de alimentación para alimentación interna200 mA or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Entrada de seguridad (IN1 a IN8): Corriente de entrada nominal5 mA approx.
Salida auxiliar (AUX1 a AUX4) (salida sin seguridad)PNP open-collector transistor with 1 output x 4- Maximum source current: 60 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Salida de control (OUT1 a OUT4): Función de retardo de encendidoIncorporated
Resistencia ambiental: Resistencia a la tensión1,000 V AC for one min.(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Salida de control (OUT1 a OUT4): Función de retardo de apagadoIncorporated
Salida de indicador de silenciamiento: protección contra cortocircuitosIncorporated
Salida de control (OUT1 a OUT4): Protección contra cortocircuitosIncorporated
Entrada de seguridad (IN1 a IN8): Duración del estado ON detectable10 ms or more
Entrada de seguridad (IN1 a IN8): Duración del estado APAGADO indetectable0.7 ms or less
Salida auxiliar (AUX1 a AUX4) (salida sin seguridad): tiempo de respuesta10 ms or less
Salida auxiliar (AUX1 a AUX4) (salida sin seguridad): protección contra cortocircuitosIncorporated
Salida auxiliar (AUX1 a AUX4) (salida sin seguridad): modo de salida (valores predeterminados de fábrica)AUX1: Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)AUX2: Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)AUX3: Reset trigger output (ON under reset release wait condition)AUX4: Lockout output (OFF when lockout)
Salida auxiliar (AUX1 a AUX4) (salida sin seguridad): modo de salida (cualquiera de las salidas auxiliares se puede personalizar mediante la herramienta de software)Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)Positive logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is ON)Positive logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is ON)Outputs A, B, C, and D of diagnosis results of input blocks (ON when logic is true)Outputs E, F, and G of internal logic circuit diagnostic results (ON when logic is true)Reset trigger output (ON under reset release wait condition)Lockout output (OFF when lockout)Muting indicator output (ON when muting / override)Monitor output in response to IN1 to IN8 (ON when input)No output (normally OFF)

Descripción del producto

Control unit for barriers and other safety products, Cat. 4(Ple) and SIL3, 4 inputs, 2 outputs, 8 pre-established logics according to cat regulations. 4 (Ple) and 1 customizable logic, self-diagnostic
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación

Top