| Parámetro | Valor |
|---|---|
| Ue | |
| corriente continua | Resistive load (DC-12) |
| Es decir | Main circuit, look monitor circuit |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Artículo | Specifications |
| Cable | UL style 2464, No.22 AWG 12-core |
| Peso | Approx. 220 g |
| Detalles | Spring lock type |
| Producto | Ultra-slim Safety door switch with solenoid interlock |
| Material | Enclosure : PA66 |
| Protección | IP 67 (IEC 60529) |
| Número de pieza | SG-B1-SA-G1 |
| Longitud del cable | 1m3.281 ft |
| Nombre del producto | Ultra-slim Safety door switch with solenoid interlock SG-B1 |
| Contactos principales | 1NC + 1NC |
| Número de producto | SG-B1-SA-G1 |
| Fuerza de enclavamiento | 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Resistencia a los golpes | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Resistencia de contacto | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Frecuencia de operación | 900 operations/hour |
| Normas aplicables | EN 60947-5-1, GS-ET-19 |
| Fuerza de apertura directa | 60 N min. |
| Circuito de monitor de puerta | AC |
| Resistencia a la vibración | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Recorrido de apertura directa | 8 mm0.315 inmin. |
| Contactos del monitor de puerta | 2NC |
| Durabilidad eléctrica | 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load) |
| Bloquear los contactos del monitor | 1NC |
| Durabilidad mecánica | 1,000,000 operations min. (GS-ET-19) |
| Corriente térmica (Ith) | ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits) |
| Normativa aplicable | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Carga inductiva (AC-15) | - |
| Carga inductiva (DC-13) | 1A |
| Velocidad de funcionamiento del actuador | 0.05 to 1.0 m/sec. |
| Tensión de aislamiento nominal (Ui) | 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit) |
| Condición de funcionamiento: Altitud | 2,000 m6,561.68 ftmax. |
| Clase de protección contra descargas eléctricas | Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Dispositivo de protección contra cortocircuitos | Use 250 V / 10 A fast acting type fuse |
| Tensión soportada al impulso (Uimp) | 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit) |
| Solenoide / Indicador: Indicador | Green LED |
| Solenoide/Indicador: Corriente nominal | 110 mA (solenoid 100 mA, LED 10 mA : initial value) |
| Condición de funcionamiento: Humedad ambiente | 45 to 85 % RH |
| Condición de funcionamiento: Grado de contaminación | 3 (Inside 2) |
| Solenoide/Indicador: Activar voltaje | Rated voltage × 85 % max. (at 20 ℃68 ℉) |
| Solenoide/Indicador: Apagar voltaje | Rated voltage × 10 % min. (at 20 ℃68 ℉) |
| Normas aplicables: Normas de uso | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Condición de funcionamiento: Temperatura ambiente | -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Solenoide/Indicador: Tensión nominal de funcionamiento | DC 24 V 100% duty cycle |
| Tensión nominal de funcionamiento (Ue) / Corriente nominal de funcionamiento (Ie) | Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación