| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Cable | 6–core cabtyre cable, 5 m16.404 ftlong |
| Observación | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW |
| Peso | Switch body (standard): 180 g approx., Actuator: 10 g approx. |
| Detalles | Compact type(Low code / Standard) |
| Producto | Non-Contact Safety Door Switch |
| Material | Switch body: PBT, PC, SUS (stainless steel), EPDMActuator: PBT |
| Número de pieza | SG-P1010-M-N |
| Peso bruto | 260 g approx. |
| Nombre del producto | Non-Contact Safety Door Switch SG-P |
| Voltaje de potencia | 24V DC+10-20% Ripple P-P 10 % or less |
| Tiempo de respuesta | • For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less• For multiple units: Time for single unit + 5 ms x (number of connected units - 1) |
| Número de producto | SG-P1010-M-N |
| Grado de contaminación | 3 |
| Consumo actual | 30 mA or less |
| Comprobar entrada y salida | Dedicated communication line between the switch body (standard) and the switch body (sub) (Note)* It is not for external input and output. (voltage range 0 V to 5 V DC)(Note) : When using the device as a single unit, connect the check input with the check output. |
| Longitud del cable conectado | • When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit• When connecting multiple units in series: Maximum total cable length of 100 m328.084 ft, maximum cable length of 20 m65.617 ftbetween two adjacent units |
| Normas aplicables: Japón | JIS B 9705-1, JIS C 0508-1 to 3 (SIL3), JIS B 9961, JIS C 8201-5-2, JIS B 9710 |
| Normas aplicables: Europa | EN ISO 13849-1 : 2015 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1 |
| Salidas de control (OSSD 1, OSSD 2) | NPN open-collector transistor 2 outputs• Maximum sink current: 100 mA• Applied voltage: Same as the power supply voltage (NPN output: between control output and 0 V)• Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable)• Leakage current: 0.2 mA or less (including power OFF state)• Maximum load capacity: 0.47 μF• Load wiring resistance: 3 Ω or less |
| Distancia de funcionamiento: Frontal / Lateral | Sao (OFF→ON): 5 mm0.197 in, Sar (ON → OFF): 15 mm0.591 in |
| Normas aplicables: América del Norte | CAN/CSA C22.2 No.14, UL508 |
| Número de unidades conectadas en serie | 30 units or less (standard 1 unit, sub 29 units) |
| Salida de control (OSSD): Circuito de protección | Incorporated |
| Normativas y certificaciones aplicables | CE Marking (Machinery Directive, RE Directive, RoHS Directive), UKCA Marking (Supply of Machinery (Safety) Regulations, RE Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (U.S.A., Canada), the U.S.'s radio regulations (FCC) (Note), Canada's radio regulations (ICES-003, RSS-310) (Note), Singapore's radio regulations (IMDA certification) (Note), Thailand's radio regulations (NBTC certification) (Note), Philippines' radio regulations (NTC certification) (Note), Korea's radio regulations (KC certification) (Note), India's radio regulations (WPC certification) (Note)(Note) : This product uses a weak radio signal for its detection operation. Please confirm compliance with applicable laws in the country of use. |
| Resistencia ambiental: Humedad ambiente | 30 to 85 % RH, storage: 30 to 95 % RH |
| Resistencia ambiental: Resistencia a los golpes | 300 m/s2(approx. 30 G), 3 times each in X, Y, and Z direction |
| Normas aplicables: Norma internacional | ISO 13849-1 : 2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119 |
| Resistencia ambiental: Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +65 ℃-13 to +149 ℉ |
| Resistencia ambiental: Grado de protección | IP65(IEC) |
| Resistencia ambiental: Resistencia a la vibración | 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions |
| Resistencia ambiental: Resistencia de aislamiento | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Salidas de control (OSSD 1, OSSD 2): Modo de operación | • When the actuator is detected (safe state): ON• When the actuator is not detected (unsafe state or lockout state): OFF• When the switch body (sub) does not detect actuator (series connection): OFF |
| Resistencia ambiental: Resistencia a la tensión | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación