Horario de atención: Lunes a Viernes 9:00-18:00
UST4C11 - UST4C11 ST4-C11 PANASONIC Controller for ST4
En stock Producto destacado

UST4C11

UST4C11 ST4-C11 PANASONIC Controller for ST4

$0.00USD
3452 en stock
Especificaciones clave
Artículo:Specifications
PFHD:Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD:More than 100 years (Note:Mean time to dangerous failure (in years))
Peso:Net weight: 180 g approxGross weight: 390 g approx
Información del proveedor
PANASONIC
PANASONIC
Productos: 4316
Normalmente se envía dentro de 2-3 días hábiles
Calidad garantizada
Envío rápido
Soporte técnico

Especificaciones técnicas

ParámetroValor
ArtículoSpecifications
PFHDRefer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFDMore than 100 years (Note:Mean time to dangerous failure (in years))
PesoNet weight: 180 g approxGross weight: 390 g approx
DetallesController
ProductoCompact Type 4 Safety Beam Sensor
MaterialEnclosure: ABS
Número de piezaST4-C11
Nombre del productoCompact Type 4 Safety Beam Sensor ST4
Cable de cableadoTerminal block connector: 0.2 to 1.5 mm2
Voltaje de potencia24 V DC +10-15 % Ripple P-P 10 % or less
Tiempo de respuestaOFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset)
Número de productoST4-C11
Salidas auxiliaresPNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Salida de lámpara de silenciamiento-(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Terminal de conexiónDetachable spring-cage terminal
Consumo actual100 mA or less (excluding sensor head ST4-Ax)
Normas aplicablesIEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x.
Cabezal de sensor aplicableST4-Ax
Cumplimiento de la directiva de marcado CEMachinery Directive, EMC Directive, RoHS Directive
Salidas auxiliares: Modo de operaciónOFF when all beams of the connected ST4-Axs are receivedON when one or more beams of the connected ST4-Axs are interrupted
Salidas de control (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Salidas auxiliares: Circuito de protecciónIncorporated
Salida de lámpara de silenciamiento: Circuito de protecciónIncorporated
Resistencia ambiental: Humedad ambiente30 to 85 % RH, Storage: 30 to 95 % RH
Resistencia ambiental: Resistencia a los golpes300 m/s2acceleration in X, Y and Z directions three times each
Resistencia ambiental: Temperatura ambiente-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Resistencia ambiental: Grado de protecciónEnclosure: IP40 (IEC)Terminal: IP20 (IEC)
Resistencia ambiental: Resistencia a la vibración10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each<
Resistencia ambiental: Resistencia de aislamiento20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure
Salidas de control (OSSD 1, OSSD 2): Modo de operaciónON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interruptedOFF during lockout
Cabezal de sensor aplicable: N.° de conexiones en serieInterference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets)
Salidas de control (OSSD1, OSSD2): Circuito de protecciónIncorporated
Resistencia ambiental: Resistencia a la tensión1,000 V AC for one min. between all supply terminals connected together and enclosure

Descripción del producto

Standard Control Unit Safety Barrier Category 4 Ple SIL 3, ST4 Series
Características clave
  • Calidad de grado industrial
  • Cumple con RoHS
  • Certificado CE
  • Garantía de 1 año

Documentos del producto

Hoja de datos

Especificaciones técnicas y datos de rendimiento

Manual de usuario

Guía de instalación y operación