| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Producción | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1.5 V or less (at 100 mA sink current) |
| Peso | Net weight: 15 g approx.Gross weight: 35 g approx. |
| Detalles | Standard type |
| Producto | Digital Fiber Sensor |
| Material | Enclosure: PolycarbonateKey switch: PolycarbonateFiber lock lever: PBT |
| Accesorio | FC-FX-1(Protection cover): 1 pc.(Note) Protection cover FC-FX-1 has been attached from the production at July, 2011. |
| Número de pieza | FX-101 |
| Longitud del cable | Total length up to 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Nombre del producto | Digital Fiber Sensor FX-100 |
| Tiempo de respuesta | Emission frequency 0: 250 micro s or less (factory default setting)Emission frequency 1: 450 micro s or lessEmission frequency 2: 500 micro s or lessEmission frequency 3: 600 micro s or less |
| Entrada externa | NPN non-contact input- Signal conditionHigh: +8 V to +V DC or OpenLow: 0 to +2 V DC(Source current 0.5 mA or less)- Input impedance: 10 kOhm approx. |
| Número de producto | FX-101 |
| Tensión de alimentación | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Función de temporizador | ON-delay / OFF-delay timer, switchable either effective or ineffective[Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms] |
| Pantalla digital | 4 digits (green) + 4 digits (red) LCD display |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistencia a los golpes | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
| Método de conexión | Connector(Note) Connector attached cable CN-14A-C2 is not attached to the models that have no ''-CC2'' at the end of the model Nos.Make sure to use the optional connector attached cable CN-14A(-R)-Cx or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd.(contact: SPHD-001T-P0.5, housing: PAP-04V-S). |
| Consumo de energía | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) |
| Iluminancia ambiental | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | –10 to +55 ℃+14 to +131℉(If 4 to 7 units are mounted close together: –10 to +50 ℃+14 to +122℉, if 8 to 16 units are mounted close together: –10 to +45 ℃+14 to +113℉) (No dew condensation or icing allowed),Storage: –20 to +70 ℃–4 to +158℉ |
| Indicador de funcionamiento | Orange LED (lights up when the output is ON) |
| Ajuste de sensibilidad | 2-point teaching / Limit teaching / Full-auto teaching |
| Resistencia a la vibración | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure(Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
| Salida:Operación de salida | Selectable either Light-ON or Dark-ON, at SET mode |
| Soportabilidad de tensión | 1,000 V AC for one min. between all supply terminals connected together and enclosure(Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
| Elemento emisor (modulado) | Red LED (Peak emission wavelength: 643 nm0.025 mil) |
| Cumplimiento de la directiva de marcado CE | EMC Directive, RoHS Directive |
| Salida: Protección contra cortocircuitos | Incorporated |
| Función de ajuste de la cantidad de emisión | 3-level + Auto setting (from production in December 2007) |
| Función de prevención de interferencias | Incorporated Emission frequency selection method (Functions at emission frequency 1, 2 or 3)(Note) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values.However, the interference prevention function does not operate at emission frequency 0 (factory default setting). |
| Función de ajuste fino de sensibilidad | Incorporated |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación