| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| Producción | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1.5 V or less (at 100 mA sink current) |
| Peso | Net weight: 15 g approx.Gross weight: 35 g approx. |
| Detalles | Long sensing range type |
| Producto | Digital Fiber Sensor |
| Material | Enclosure: PolycarbonateKey switch: PolycarbonateFiber lock lever: PBT |
| Accesorio | FC-FX-1(Protection cover): 1 pc.(Note) Protection cover FC-FX-1 has been attached from the production at July, 2011. |
| Número de pieza | FX-102-Z |
| Longitud del cable | Total length up to 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Nombre del producto | Digital Fiber Sensor FX-100 |
| Tiempo de respuesta | Emission frequency 1: 2.5 ms or less (factory default setting)Emission frequency 2: 2.8 ms or lessEmission frequency 3: 3.2 ms or lessEmission frequency 4: 5.0 ms or less |
| Entrada externa | NPN non-contact input- Signal conditionHigh: +8 V to +V DC or OpenLow: 0 to +2 V DC(Source current 0.5 mA or less)- Input impedance: 10 kOhm approx. |
| Número de producto | FX-102-Z |
| Tensión de alimentación | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Función de temporizador | ON-delay / OFF-delay timer, switchable either effective or ineffective[Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms] |
| Pantalla digital | 4 digits (green) + 4 digits (red) LCD display |
| Humedad ambiental | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Resistencia a los golpes | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
| Método de conexión | Connector(Note) Connector attached cable CN-14A-C2 is not attached to the models that have no ''-CC2'' at the end of the model Nos.Make sure to use the optional connector attached cable CN-14A(-R)-Cx or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd.(contact: SPHD-001T-P0.5, housing: PAP-04V-S). |
| Consumo de energía | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) |
| Iluminancia ambiental | Incandescent light: 3,000 lx or less at the light-receiving face |
| Temperatura ambiente | –10 to +55 ℃+14 to +131℉(If 4 to 7 units are mounted close together: –10 to +50 ℃+14 to +122℉, if 8 to 16 units are mounted close together: –10 to +45 ℃+14 to +113℉) (No dew condensation or icing allowed),Storage: –20 to +70 ℃–4 to +158℉ |
| Indicador de funcionamiento | Orange LED (lights up when the output is ON) |
| Ajuste de sensibilidad | 2-point teaching / Limit teaching / Full-auto teaching |
| Resistencia a la vibración | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Resistencia de aislamiento | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure(Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
| Salida:Operación de salida | Selectable either Light-ON or Dark-ON, at SET mode |
| Soportabilidad de tensión | 1,000 V AC for one min. between all supply terminals connected together and enclosure(Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
| Elemento emisor (modulado) | Red LED (Peak emission wavelength: 643 nm0.025 mil) |
| Cumplimiento de la directiva de marcado CE | EMC Directive, RoHS Directive |
| Salida: Protección contra cortocircuitos | Incorporated |
| Función de ajuste de la cantidad de emisión | 3-level + Auto setting (from production in December 2007) |
| Función de prevención de interferencias | Incorporated Emission frequency selection method (Functions at emission frequency 1, 2, 3 or 4)(Note) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values. |
| Función de ajuste fino de sensibilidad | Incorporated |
Especificaciones técnicas y datos de rendimiento