| Parámetro | Valor |
|---|---|
| Artículo | Specifications |
| PFHD | 4.95 × 10-9 |
| Cable | 0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m1.640 ftlong with connector |
| MTTFD | 100 years or more |
| Detalles | Min. sensing object ø14 mmø0.551 intype (10 mm0.394 inbeam pitch) [Pigtailed type] |
| Producto | Ultra-slim Safety Light Curtain [Type 4 PLe SIL3] |
| Material | Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloy |
| Paso de viga | 10 mm0.394 in |
| Accesorios | MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR14 (Test rod): 1 No. |
| Número de pieza | SF4C-F63-J05 |
| Nombre del producto | Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C |
| Función ELCA | Incorporated (reducing mutual interference automatically) |
| Voltaje de potencia | 24 V DC +10-15 % Ripple P-P 10 % or less |
| Tiempo de respuesta | OFF response: 9 ms or lessON response: 90 ms or less |
| Número de producto | SF4C-F63-J05 |
| Extensión de cable | Extension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver). |
| Función de silenciamiento | Incorporated |
| Rango de operación | 0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Elemento emisor | Infrared LED (Peak emission wavelength: 855 nm0.034 mil) |
| Grado de contaminación | 3 |
| Función de anulación | Incorporated |
| Altura de protección | 640 mm25.197 in |
| Función de enclavamiento | Incorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| Altitud de operación | 2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.) |
| Funciones opcionales | Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required. |
| Iluminancia ambiental | Incandescent light: 5,000 lx or less at the light-receiving face |
| Mínimo objeto detectado | ø14 mmø0.551 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed. |
| Número de canales de haz | 63 |
| Función de entrada de seguridad | Incorporated (safety contact) |
| Ángulo de apertura efectivo | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)] |
| Normas aplicables: Japón | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3) |
| Normas aplicables: Europa | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Función de entrada de prueba/reinicio | Incorporated |
| Salidas de control (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less |
| Normas aplicables: América del Norte | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| Función de monitorización de dispositivos externos | Incorporated |
| Salida auxiliar (salida sin seguridad) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable) |
| Normativas y certificaciones aplicables | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| Resistencia ambiental: Humedad ambiente | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Resistencia ambiental: Resistencia a los golpes | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Peso neto (Total de emisor y receptor) | 600 g approx. |
| Normas aplicables: Norma internacional | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3) |
| Resistencia ambiental: Temperatura ambiente | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉ |
| Resistencia ambiental: Grado de protección | IP67 / IP65 (IEC) |
| Resistencia ambiental: Resistencia a la vibración | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Resistencia ambiental: Resistencia de aislamiento | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Salidas de control (OSSD 1, OSSD 2): Modo de operación | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed. |
| Salidas de control (OSSD1, OSSD2): Circuito de protección | Incorporated |
| Resistencia ambiental: Resistencia a la tensión | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Salida auxiliar (salida sin seguridad): modo de funcionamiento | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller). |
| Salida auxiliar (salida sin seguridad): circuito de protección | Incorporated |
| Consumo de corriente: Se enciende el indicador multiusos grande. | Emitter: 120 mA or lessReceiver: 125 mA or less |
| Consumo de corriente: Luces indicadoras multiusos grandes apagadas | Emitter: 85 mA or lessReceiver: 95 mA or less |
Especificaciones técnicas y datos de rendimiento
Guía de instalación y operación